FabDigitFabDigit

Steel 4024-A vs 4024-N

Steel · 4024 temper comparison

4024-A and 4024-N are two conditions of the same steel grade, 4024: A (solution annealed) versus N (normalized). The chemistry is identical, so every difference below comes from the condition. 4024-N is the stronger of the two: yield strength 370 MPa (53.7 ksi) against 290 MPa (42.1 ksi) for 4024-A, about 28% more; tensile strength follows at 530 MPa (76.9 ksi) vs 450 MPa (65.3 ksi). In exchange, 4024-A is the more ductile: elongation 30% versus 27% for 4024-N, and 4024-N is harder (156 HB vs 131 HB).

4024-AChoose it when the part is bent, formed or impact-loaded.

4024-NChoose it when strength drives the design.

4024-A vs 4024-N: properties

4024-A4024-N

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

450 MPa65.3 ksi
530 MPa76.9 ksi

Yield Strength (0.2% offset)

290 MPa42.1 ksi
370 MPa53.7 ksi

Elongation at Break

30%
27%

Shear Strength

300 MPa43.5 ksi
350 MPa50.8 ksi

Fatigue Strength (Endurance Limit)

210 MPa30.5 ksi
250 MPa36.3 ksi

Charpy V-Notch Impact (RT)

65 J47.9 ft·lbf
70 J51.6 ft·lbf

Hardness, Brinell

131 HB
156 HB

Hardness, Rockwell B

73 HRB
82 HRB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Reduction in Area 58%

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,510°C2,750 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

43 W/m·K24.8 BTU/hr·ft·°F
42 W/m·K24.3 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.2 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -30°C-22 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

8 % IACS
7.8 % IACS

Electrical Resistivity

2.15×10⁻⁷ Ω·m8.46 µΩ·in
2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 11 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

75 / 100
72 / 100

Machinability Rating (AISI 1212 = 100 %)

78%
75%

Weldability

38 / 100
35 / 100

Formability (cold)

62 / 100
52 / 100

Same in both: Brazeability / Solderability 70 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 30 MJ/kg12,898 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 50 L/kg6 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale4024

4024-A vs 4024-N — frequently asked

Is 4024-N stronger than 4024-A?

Yes. 4024-N has a typical yield strength of 370 MPa (53.7 ksi) against 290 MPa (42.1 ksi) for 4024-A — about 28% more. Tensile strength is 530 MPa (76.9 ksi) vs 450 MPa (65.3 ksi).

Which condition does FabDigit quote by default, A or N?

HR is the default 4024 condition in the FabDigit quote flow (neither A nor N). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 4024-A over 4024-N?

Pick 4024-A when the part is bent, formed or impact-loaded. Pick 4024-N when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 4024-A and 4024-N side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.