FabDigitFabDigit

Steel 4-79 Mo-Permalloy 1/2H vs 4-79 Mo-Permalloy-CD

Steel · 4-79 Mo-Permalloy temper comparison

4-79 Mo-Permalloy 1/2H and 4-79 Mo-Permalloy-CD are two conditions of the same steel grade, 4-79 Mo-Permalloy: 1/2H (half hard) versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. 4-79 Mo-Permalloy-CD is the stronger of the two: yield strength 620 MPa (89.9 ksi) against 560 MPa (81.2 ksi) for 4-79 Mo-Permalloy 1/2H, about 11% more; tensile strength follows at 800 MPa (116 ksi) vs 760 MPa (110 ksi). 4-79 Mo-Permalloy-CD is the more ductile: elongation 15% versus 12% for 4-79 Mo-Permalloy 1/2H, and 4-79 Mo-Permalloy-CD is harder (208 HB vs 190 HB).

4-79 Mo-Permalloy-CDChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

4-79 Mo-Permalloy 1/2H vs 4-79 Mo-Permalloy-CD: properties

4-79 Mo-Permalloy 1/2H4-79 Mo-Permalloy-CD

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

760 MPa110 ksi
800 MPa116 ksi

Yield Strength (0.2% offset)

560 MPa81.2 ksi
620 MPa89.9 ksi

Elongation at Break

12%
15%

Reduction in Area

35%
40%

Fatigue Strength (Endurance Limit)

340 MPa49.3 ksi
350 MPa50.8 ksi

Hardness, Brinell

190 HB
208 HB

Hardness, Rockwell B

95 HRB
97 HRB

Hardness, Vickers

200 HV
220 HV

Same in both: Elastic (Young's) Modulus 212 GPa30.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 175 GPa25.4 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 8.74 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,450°C2,642 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 19 W/m·K11 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.5 µm/m·K6.9 µin/in·°F · Max Service Temperature (continuous) 350°C662 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 3.1 % IACS · Electrical Resistivity 5.6×10⁻⁷ Ω·m22 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.3 V · Corrosion Resistance 45 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

34 / 100
38 / 100

Machinability Rating (AISI 1212 = 100 %)

34%
38%

Formability (cold)

45 / 100
35 / 100

Same in both: Weldability 58 / 100 · Castability 40 / 100 · Brazeability / Solderability 70 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 140 MJ/kg60,189 BTU/lb · Embodied Carbon (primary production) 10 kg CO₂/kg · Embodied Water 200 L/kg24 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale4-79 Mo-Permalloy

4-79 Mo-Permalloy 1/2H vs 4-79 Mo-Permalloy-CD — frequently asked

Is 4-79 Mo-Permalloy-CD stronger than 4-79 Mo-Permalloy 1/2H?

Yes. 4-79 Mo-Permalloy-CD has a typical yield strength of 620 MPa (89.9 ksi) against 560 MPa (81.2 ksi) for 4-79 Mo-Permalloy 1/2H — about 11% more. Tensile strength is 800 MPa (116 ksi) vs 760 MPa (110 ksi).

Which condition does FabDigit quote by default, 1/2H or CD?

Annealed is the default 4-79 Mo-Permalloy condition in the FabDigit quote flow (neither 1/2H nor CD). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 4-79 Mo-Permalloy 1/2H over 4-79 Mo-Permalloy-CD?

Pick 4-79 Mo-Permalloy-CD when strength drives the design, or when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 4-79 Mo-Permalloy 1/2H and 4-79 Mo-Permalloy-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.