FabDigitFabDigit

Steel 3J53-HR vs 3J53-ST

Steel · 3J53 temper comparison

3J53-HR and 3J53-ST are two conditions of the same steel grade, 3J53: HR (hot rolled) versus ST (solution annealed). The chemistry is identical, so every difference below comes from the condition. 3J53-HR is the stronger of the two: yield strength 400 MPa (58 ksi) against 330 MPa (47.9 ksi) for 3J53-ST, about 21% more; tensile strength follows at 800 MPa (116 ksi) vs 760 MPa (110 ksi). In exchange, 3J53-ST is the more ductile: elongation 35% versus 28% for 3J53-HR, and 3J53-HR is harder (210 HB vs 172 HB).

3J53-HRChoose it when strength drives the design.

3J53-STChoose it when the part is bent, formed or impact-loaded.

3J53-HR vs 3J53-ST: properties

3J53-HR3J53-ST

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

800 MPa116 ksi
760 MPa110 ksi

Yield Strength (0.2% offset)

400 MPa58 ksi
330 MPa47.9 ksi

Elongation at Break

28%
35%

Reduction in Area

50%
55%

Compressive Strength

410 MPa59.5 ksi
340 MPa49.3 ksi

Shear Strength

505 MPa73.2 ksi
480 MPa69.6 ksi

Fatigue Strength (Endurance Limit)

320 MPa46.4 ksi
300 MPa43.5 ksi

Charpy V-Notch Impact (RT)

80 J59 ft·lbf
90 J66.4 ft·lbf

Hardness, Brinell

210 HB
172 HB

Hardness, Rockwell B

95 HRB
88 HRB

Hardness, Vickers

215 HV
180 HV

Same in both: Elastic (Young's) Modulus 155 GPa22.5 Msi · Shear Modulus 63 GPa9.1 Msi · Bulk Modulus 145 GPa21 Msi · Poisson's Ratio 0.31

Physical

Density and transition temperatures.

Same in both: Density 8.14 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,450°C2,642 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 12.6 W/m·K7.3 BTU/hr·ft·°F · Specific Heat Capacity 500 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 7.9 µm/m·K4.4 µin/in·°F · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -50°C-58 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.2 % IACS · Electrical Resistivity 8×10⁻⁷ Ω·m31.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.35 V · Corrosion Resistance 40 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
35 / 100

Machinability Rating (AISI 1212 = 100 %)

25%
30%

Formability (cold)

55 / 100
75 / 100

Same in both: Weldability 50 / 100 · Brazeability / Solderability 55 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 130 MJ/kg55,890 BTU/lb · Embodied Carbon (primary production) 9 kg CO₂/kg · Embodied Water 220 L/kg26.4 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale3J53

3J53-HR vs 3J53-ST — frequently asked

Is 3J53-HR stronger than 3J53-ST?

Yes. 3J53-HR has a typical yield strength of 400 MPa (58 ksi) against 330 MPa (47.9 ksi) for 3J53-ST — about 21% more. Tensile strength is 800 MPa (116 ksi) vs 760 MPa (110 ksi).

Which condition does FabDigit quote by default, HR or ST?

ST is the default 3J53 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 3J53-HR or 3J53-ST?

3J53-ST. Its machinability rates fair (35/100) against poor (30/100) for 3J53-HR.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 3J53-HR and 3J53-ST side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.