FabDigitFabDigit

Steel 30CrMnSi-A vs 30CrMnSi-CD

Steel · 30CrMnSi temper comparison

30CrMnSi-A and 30CrMnSi-CD are two conditions of the same steel grade, 30CrMnSi: A (solution annealed) versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. 30CrMnSi-CD is the stronger of the two: yield strength 750 MPa (109 ksi) against 480 MPa (69.6 ksi) for 30CrMnSi-A, about 56% more; tensile strength follows at 900 MPa (131 ksi) vs 750 MPa (109 ksi). In exchange, 30CrMnSi-A is the more ductile: elongation 20% versus 10% for 30CrMnSi-CD, and 30CrMnSi-CD is harder (270 HB vs 210 HB). 30CrMnSi-A runs hotter in service (400°C vs 300°C continuous). On the shop floor, 30CrMnSi-A welds better (50 vs 38 out of 100).

30CrMnSi-AChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

30CrMnSi-CDChoose it when strength drives the design.

30CrMnSi-A vs 30CrMnSi-CD: properties

30CrMnSi-A30CrMnSi-CD

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

750 MPa109 ksi
900 MPa131 ksi

Yield Strength (0.2% offset)

480 MPa69.6 ksi
750 MPa109 ksi

Elongation at Break

20%
10%

Reduction in Area

55%
40%

Compressive Strength

930 MPa135 ksi
780 MPa113 ksi

Shear Strength

450 MPa65.3 ksi
540 MPa78.3 ksi

Fatigue Strength (Endurance Limit)

350 MPa50.8 ksi
400 MPa58 ksi

Fracture Toughness (K_IC)

65 MPa·√m59.2 ksi·√in
60 MPa·√m54.6 ksi·√in

Charpy V-Notch Impact (RT)

60 J44.3 ft·lbf
30 J22.1 ft·lbf

Hardness, Brinell

210 HB
270 HB

Hardness, Rockwell C

36 HRC
27 HRC

Hardness, Vickers

355 HV
284 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,490°C2,714 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

37 W/m·K21.4 BTU/hr·ft·°F
38 W/m·K22 BTU/hr·ft·°F

Max Service Temperature (continuous)

400°C752 °F
300°C572 °F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.5 µm/m·K6.4 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -70°C-94 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7 % IACS · Electrical Resistivity 2.5×10⁻⁷ Ω·m9.84 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
52 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
58%

Weldability

50 / 100
38 / 100

Formability (cold)

45 / 100
25 / 100

Same in both: Brazeability / Solderability 55 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 34 MJ/kg14,617 BTU/lb · Embodied Carbon (primary production) 2.3 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale30CrMnSi

30CrMnSi-A vs 30CrMnSi-CD — frequently asked

Is 30CrMnSi-CD stronger than 30CrMnSi-A?

Yes. 30CrMnSi-CD has a typical yield strength of 750 MPa (109 ksi) against 480 MPa (69.6 ksi) for 30CrMnSi-A — about 56% more. Tensile strength is 900 MPa (131 ksi) vs 750 MPa (109 ksi).

Which condition does FabDigit quote by default, A or CD?

QT880-520 is the default 30CrMnSi condition in the FabDigit quote flow (neither A nor CD). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, 30CrMnSi-A or 30CrMnSi-CD?

30CrMnSi-A. Its weldability rates fair (50/100) against fair (38/100) for 30CrMnSi-CD.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 30CrMnSi-A and 30CrMnSi-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.