Steel 30CrMnSi-A vs 30CrMnSi-CD
Steel · 30CrMnSi temper comparison
30CrMnSi-A and 30CrMnSi-CD are two conditions of the same steel grade, 30CrMnSi: A (solution annealed) versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. 30CrMnSi-CD is the stronger of the two: yield strength 750 MPa (109 ksi) against 480 MPa (69.6 ksi) for 30CrMnSi-A, about 56% more; tensile strength follows at 900 MPa (131 ksi) vs 750 MPa (109 ksi). In exchange, 30CrMnSi-A is the more ductile: elongation 20% versus 10% for 30CrMnSi-CD, and 30CrMnSi-CD is harder (270 HB vs 210 HB). 30CrMnSi-A runs hotter in service (400°C vs 300°C continuous). On the shop floor, 30CrMnSi-A welds better (50 vs 38 out of 100).
30CrMnSi-AChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.
30CrMnSi-CDChoose it when strength drives the design.
30CrMnSi-A vs 30CrMnSi-CD: propertiesHow to read these bars
- One bar per material. A full bar is the highest value among all steel grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
How to read these bars
- One bar per material. A full bar is the highest value among all steel grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
Mechanical
Strength, stiffness, ductility and hardness at room temperature.
Tensile Strength (Ultimate)
Yield Strength (0.2% offset)
Elongation at Break
Reduction in Area
Compressive Strength
Shear Strength
Fatigue Strength (Endurance Limit)
Fracture Toughness (K_IC)
Charpy V-Notch Impact (RT)
Hardness, Brinell
Hardness, Rockwell C
Hardness, Vickers
Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29
Physical
Density and transition temperatures.
Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,490°C2,714 °F
Thermal
How each material carries heat and how hot it can run.
Thermal Conductivity
Max Service Temperature (continuous)
Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.5 µm/m·K6.4 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -70°C-94 °F
Electrical
Conductivity and insulation.
Same in both: Electrical Conductivity 7 % IACS · Electrical Resistivity 2.5×10⁻⁷ Ω·m9.84 µΩ·in
Chemical & Environmental
Corrosion and environmental resistance (0–100 scores).
Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 12 / 100
Manufacturability
FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.
Machinability
Machinability Rating (AISI 1212 = 100 %)
Weldability
Formability (cold)
Same in both: Brazeability / Solderability 55 / 100 · Polishability 65 / 100
Sustainability
Primary-production footprint per kilogram.
Same in both: Embodied Energy (primary production) 34 MJ/kg14,617 BTU/lb · Embodied Carbon (primary production) 2.3 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%
Strength versus weight
Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.
30CrMnSi-A vs 30CrMnSi-CD — frequently asked
Is 30CrMnSi-CD stronger than 30CrMnSi-A?
Yes. 30CrMnSi-CD has a typical yield strength of 750 MPa (109 ksi) against 480 MPa (69.6 ksi) for 30CrMnSi-A — about 56% more. Tensile strength is 900 MPa (131 ksi) vs 750 MPa (109 ksi).
Which condition does FabDigit quote by default, A or CD?
QT880-520 is the default 30CrMnSi condition in the FabDigit quote flow (neither A nor CD). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.
Which welds better, 30CrMnSi-A or 30CrMnSi-CD?
30CrMnSi-A. Its weldability rates fair (50/100) against fair (38/100) for 30CrMnSi-CD.
Ready to make it?
Upload a CAD file and FabDigit prices the part in 30CrMnSi-A and 30CrMnSi-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.
Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.