300M-CD and 300M-HR are two conditions of the same steel grade, 300M: CD (cold drawn) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. 300M-CD is the stronger of the two: yield strength 950 MPa (138 ksi) against 760 MPa (110 ksi) for 300M-HR, about 25% more. In exchange, 300M-HR is the more ductile: elongation 12% versus 9% for 300M-CD, and 300M-CD is harder (340 HB vs 320 HB).

300M-CDChoose it when strength drives the design.

300M-HRChoose it when the part is bent, formed or impact-loaded.

300M-CD vs 300M-HR: properties

300M-CD300M-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

1,150 MPa167 ksi
1,100 MPa160 ksi

Yield Strength (0.2% offset)

950 MPa138 ksi
760 MPa110 ksi

Elongation at Break

9%
12%

Reduction in Area

40%
45%

Compressive Strength

1,000 MPa145 ksi
800 MPa116 ksi

Shear Strength

690 MPa100 ksi
660 MPa95.7 ksi

Fatigue Strength (Endurance Limit)

540 MPa78.3 ksi
520 MPa75.4 ksi

Fracture Toughness (K_IC)

88 MPa·√m80.1 ksi·√in
95 MPa·√m86.5 ksi·√in

Charpy V-Notch Impact (RT)

35 J25.8 ft·lbf
45 J33.2 ft·lbf

Hardness, Brinell

340 HB
320 HB

Hardness, Rockwell C

36 HRC
34 HRC

Hardness, Vickers

355 HV
335 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 78 GPa11.3 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.83 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,470°C2,678 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

38 W/m·K22 BTU/hr·ft·°F
40 W/m·K23.1 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 475 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -73°C-99 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

7.5 % IACS
8 % IACS

Electrical Resistivity

2.3×10⁻⁷ Ω·m9.06 µΩ·in
2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
38 / 100

Machinability Rating (AISI 1212 = 100 %)

32%
35%

Weldability

22 / 100
25 / 100

Formability (cold)

12 / 100
18 / 100

Same in both: Castability 25 / 100 · Brazeability / Solderability 25 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 40 MJ/kg17,197 BTU/lb · Embodied Carbon (primary production) 2.8 kg CO₂/kg · Embodied Water 70 L/kg8.4 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale300M

300M-CD vs 300M-HR — frequently asked

Is 300M-CD stronger than 300M-HR?

Yes. 300M-CD has a typical yield strength of 950 MPa (138 ksi) against 760 MPa (110 ksi) for 300M-HR — about 25% more. Tensile strength is 1,150 MPa (167 ksi) vs 1,100 MPa (160 ksi).

Which condition does FabDigit quote by default, CD or HR?

HR is the default 300M condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 300M-CD over 300M-HR?

Pick 300M-CD when strength drives the design. Pick 300M-HR when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 300M-CD and 300M-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.