FabDigitFabDigit

Steel 23MnB4 +U vs 23MnB4 +U+C

Steel · 23MnB4 temper comparison

23MnB4 +U and 23MnB4 +U+C are two conditions of the same steel grade, 23MnB4: +U (hot rolled) versus +U+C (untreated, cold drawn). The chemistry is identical, so every difference below comes from the condition. 23MnB4 +U+C is the stronger of the two: yield strength 580 MPa (84.1 ksi) against 380 MPa (55.1 ksi) for 23MnB4 +U, about 53% more; tensile strength follows at 660 MPa (95.7 ksi) vs 570 MPa (82.7 ksi). In exchange, 23MnB4 +U is the more ductile: elongation 20% versus 10% for 23MnB4 +U+C, and 23MnB4 +U+C is harder (200 HB vs 170 HB).

23MnB4 +UChoose it when the part is bent, formed or impact-loaded.

23MnB4 +U+CChoose it when strength drives the design.

23MnB4 +U vs 23MnB4 +U+C: properties

23MnB4 +U23MnB4 +U+C

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

570 MPa82.7 ksi
660 MPa95.7 ksi

Yield Strength (0.2% offset)

380 MPa55.1 ksi
580 MPa84.1 ksi

Elongation at Break

20%
10%

Reduction in Area

55%
50%

Shear Strength

345 MPa50 ksi
400 MPa58 ksi

Fatigue Strength (Endurance Limit)

260 MPa37.7 ksi
300 MPa43.5 ksi

Charpy V-Notch Impact (RT)

50 J36.9 ft·lbf
30 J22.1 ft·lbf

Hardness, Brinell

170 HB
200 HB

Hardness, Rockwell B

86 HRB
94 HRB

Hardness, Vickers

180 HV
210 HV

Same in both: Elastic (Young's) Modulus 207 GPa30 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Fracture Toughness (K_IC) 70 MPa·√m63.7 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,505°C2,741 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 45 W/m·K26 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.3 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 300°C572 °F · Min Service Temperature -30°C-22 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 9 % IACS · Electrical Resistivity 1.9×10⁻⁷ Ω·m7.48 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

60 / 100
65 / 100

Machinability Rating (AISI 1212 = 100 %)

65%
70%

Formability (cold)

70 / 100
55 / 100

Same in both: Weldability 45 / 100 · Brazeability / Solderability 60 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale23MnB4

23MnB4 +U vs 23MnB4 +U+C — frequently asked

Is 23MnB4 +U+C stronger than 23MnB4 +U?

Yes. 23MnB4 +U+C has a typical yield strength of 580 MPa (84.1 ksi) against 380 MPa (55.1 ksi) for 23MnB4 +U — about 53% more. Tensile strength is 660 MPa (95.7 ksi) vs 570 MPa (82.7 ksi).

Which condition does FabDigit quote by default, +U or +U+C?

+AC+C is the default 23MnB4 condition in the FabDigit quote flow (neither +U nor +U+C). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 23MnB4 +U or 23MnB4 +U+C?

23MnB4 +U+C, by a small margin. Both rate good for machinability — 65/100 against 60/100 for 23MnB4 +U.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 23MnB4 +U and 23MnB4 +U+C side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.