FabDigitFabDigit

Steel 23B2 +AC vs 23B2 +U

Steel · 23B2 temper comparison

23B2 +AC and 23B2 +U are two conditions of the same steel grade, 23B2: +AC (spheroidize annealed) versus +U (hot rolled). The chemistry is identical, so every difference below comes from the condition. 23B2 +U is the stronger of the two: yield strength 380 MPa (55.1 ksi) against 300 MPa (43.5 ksi) for 23B2 +AC, about 27% more; tensile strength follows at 560 MPa (81.2 ksi) vs 450 MPa (65.3 ksi). In exchange, 23B2 +AC is the more ductile: elongation 25% versus 22% for 23B2 +U, and 23B2 +U is harder (165 HB vs 128 HB).

23B2 +ACChoose it when the part is bent, formed or impact-loaded.

23B2 +UChoose it when strength drives the design.

23B2 +AC vs 23B2 +U: properties

23B2 +AC23B2 +U

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

450 MPa65.3 ksi
560 MPa81.2 ksi

Yield Strength (0.2% offset)

300 MPa43.5 ksi
380 MPa55.1 ksi

Elongation at Break

25%
22%

Reduction in Area

68%
58%

Shear Strength

300 MPa43.5 ksi
365 MPa52.9 ksi

Fatigue Strength (Endurance Limit)

205 MPa29.7 ksi
250 MPa36.3 ksi

Charpy V-Notch Impact (RT)

80 J59 ft·lbf
55 J40.6 ft·lbf

Hardness, Brinell

128 HB
165 HB

Hardness, Rockwell B

71 HRB
85 HRB

Hardness, Vickers

134 HV
173 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,460°C2,660 °F · Liquidus Temperature 1,510°C2,750 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 48 W/m·K27.7 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.3 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 350°C662 °F · Min Service Temperature -30°C-22 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10 % IACS · Electrical Resistivity 1.7×10⁻⁷ Ω·m6.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 11 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
62 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
65%

Weldability

74 / 100
72 / 100

Formability (cold)

92 / 100
72 / 100

Same in both: Brazeability / Solderability 60 / 100 · Polishability 50 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale23B2

23B2 +AC vs 23B2 +U — frequently asked

Is 23B2 +U stronger than 23B2 +AC?

Yes. 23B2 +U has a typical yield strength of 380 MPa (55.1 ksi) against 300 MPa (43.5 ksi) for 23B2 +AC — about 27% more. Tensile strength is 560 MPa (81.2 ksi) vs 450 MPa (65.3 ksi).

Which condition does FabDigit quote by default, +AC or +U?

+AC+C is the default 23B2 condition in the FabDigit quote flow (neither +AC nor +U). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 23B2 +AC or 23B2 +U?

23B2 +U, by a small margin. Both rate good for machinability — 62/100 against 55/100 for 23B2 +AC.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 23B2 +AC and 23B2 +U side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.