FabDigitFabDigit

Steel 20NiCrMoS2-2 +C vs 20NiCrMoS2-2 +H

Steel · 20NiCrMoS2-2 temper comparison

20NiCrMoS2-2 +C and 20NiCrMoS2-2 +H are two conditions of the same steel grade, 20NiCrMoS2-2: +C (cold drawn) versus +H (guaranteed hardenability band (Jominy); properties after carburize,…). The chemistry is identical, so every difference below comes from the condition. 20NiCrMoS2-2 +H is the stronger of the two: yield strength 680 MPa (98.6 ksi) against 560 MPa (81.2 ksi) for 20NiCrMoS2-2 +C, about 21% more; tensile strength follows at 950 MPa (138 ksi) vs 690 MPa (100 ksi). 20NiCrMoS2-2 +H is harder — 285 HB against 210 HB for 20NiCrMoS2-2 +C — which matters for wear surfaces and threads. 20NiCrMoS2-2 +C runs hotter in service (350°C vs 180°C continuous). On the shop floor, 20NiCrMoS2-2 +C machines more easily (good vs poor), 20NiCrMoS2-2 +C welds better (fair vs poor), and 20NiCrMoS2-2 +C forms better (fair vs not recommended).

20NiCrMoS2-2 +CChoose it when the part sees heat, or when the part is machined in volume.

20NiCrMoS2-2 +HChoose it when strength drives the design, or when surface hardness matters.

20NiCrMoS2-2 +C vs 20NiCrMoS2-2 +H: properties

20NiCrMoS2-2 +C20NiCrMoS2-2 +H

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

207 GPa30 Msi
208 GPa30.2 Msi

Tensile Strength (Ultimate)

690 MPa100 ksi
950 MPa138 ksi

Yield Strength (0.2% offset)

560 MPa81.2 ksi
680 MPa98.6 ksi

Reduction in Area

40%
45%

Compressive Strength

560 MPa81.2 ksi
700 MPa102 ksi

Shear Strength

420 MPa60.9 ksi
600 MPa87 ksi

Fatigue Strength (Endurance Limit)

300 MPa43.5 ksi
450 MPa65.3 ksi

Fracture Toughness (K_IC)

80 MPa·√m72.8 ksi·√in
70 MPa·√m63.7 ksi·√in

Charpy V-Notch Impact (RT)

35 J25.8 ft·lbf
45 J33.2 ft·lbf

Hardness, Brinell

210 HB
285 HB

Hardness, Rockwell B

95 HRB
84 HRB

Hardness, Vickers

220 HV
720 HV

Same in both: Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Elongation at Break 11%

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,490°C2,714 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

44 W/m·K25.4 BTU/hr·ft·°F
42 W/m·K24.3 BTU/hr·ft·°F

Max Service Temperature (continuous)

350°C662 °F
180°C356 °F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.6 µm/m·K6.4 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

8.4 % IACS
8.5 % IACS

Electrical Resistivity

2.15×10⁻⁷ Ω·m8.46 µΩ·in
2.1×10⁻⁷ Ω·m8.27 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

69 / 100
20 / 100

Machinability Rating (AISI 1212 = 100 %)

83%
15%

Weldability

42 / 100
15 / 100

Formability (cold)

38 / 100
5 / 100

Same in both: Brazeability / Solderability 60 / 100 · Polishability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 30 MJ/kg12,898 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 55 L/kg6.6 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale20NiCrMoS2-2

20NiCrMoS2-2 +C vs 20NiCrMoS2-2 +H — frequently asked

Is 20NiCrMoS2-2 +H stronger than 20NiCrMoS2-2 +C?

Yes. 20NiCrMoS2-2 +H has a typical yield strength of 680 MPa (98.6 ksi) against 560 MPa (81.2 ksi) for 20NiCrMoS2-2 +C — about 21% more. Tensile strength is 950 MPa (138 ksi) vs 690 MPa (100 ksi).

Which condition does FabDigit quote by default, +C or +H?

+AC is the default 20NiCrMoS2-2 condition in the FabDigit quote flow (neither +C nor +H). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 20NiCrMoS2-2 +C or 20NiCrMoS2-2 +H?

20NiCrMoS2-2 +C. Its machinability rates good (69/100) against poor (20/100) for 20NiCrMoS2-2 +H; for welding the order is 20NiCrMoS2-2 +C first (fair, 42/100) then 20NiCrMoS2-2 +H (poor, 15/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 20NiCrMoS2-2 +C and 20NiCrMoS2-2 +H side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.