FabDigitFabDigit

Steel 20MnCr5 Annealed vs 20MnCr5-CR

Steel · 20MnCr5 temper comparison

20MnCr5 Annealed and 20MnCr5-CR are two conditions of the same steel grade, 20MnCr5: Annealed versus CR (cold rolled). The chemistry is identical, so every difference below comes from the condition. 20MnCr5-CR is the stronger of the two: yield strength 560 MPa (81.2 ksi) against 350 MPa (50.8 ksi) for 20MnCr5 Annealed, about 60% more; tensile strength follows at 720 MPa (104 ksi) vs 560 MPa (81.2 ksi). In exchange, 20MnCr5 Annealed is the more ductile: elongation 24% versus 10% for 20MnCr5-CR, and 20MnCr5-CR is harder (215 HB vs 170 HB). 20MnCr5 Annealed runs hotter in service (250°C vs 200°C continuous). On the shop floor, 20MnCr5 Annealed machines more easily (65 vs 55 out of 100).

20MnCr5 AnnealedChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

20MnCr5-CRChoose it when strength drives the design.

20MnCr5 Annealed vs 20MnCr5-CR: properties

20MnCr5 Annealed20MnCr5-CR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

560 MPa81.2 ksi
720 MPa104 ksi

Yield Strength (0.2% offset)

350 MPa50.8 ksi
560 MPa81.2 ksi

Elongation at Break

24%
10%

Reduction in Area

55%
35%

Compressive Strength

470 MPa68.2 ksi
570 MPa82.7 ksi

Shear Strength

460 MPa66.7 ksi
440 MPa63.8 ksi

Fatigue Strength (Endurance Limit)

340 MPa49.3 ksi
330 MPa47.9 ksi

Charpy V-Notch Impact (RT)

60 J44.3 ft·lbf
25 J18.4 ft·lbf

Hardness, Brinell

170 HB
215 HB

Hardness, Rockwell B

94 HRB
95 HRB

Hardness, Vickers

180 HV
226 HV

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,495°C2,723 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

250°C482 °F
200°C392 °F

Same in both: Thermal Conductivity 44 W/m·K25.4 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.1 µm/m·K6.2 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 8.2 % IACS · Electrical Resistivity 2.1×10⁻⁷ Ω·m8.27 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

65 / 100
55 / 100

Machinability Rating (AISI 1212 = 100 %)

70%
60%

Formability (cold)

70 / 100
45 / 100

Same in both: Weldability 45 / 100 · Castability 25 / 100 · Brazeability / Solderability 55 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 27 MJ/kg11,608 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale20MnCr5

20MnCr5 Annealed vs 20MnCr5-CR — frequently asked

Is 20MnCr5-CR stronger than 20MnCr5 Annealed?

Yes. 20MnCr5-CR has a typical yield strength of 560 MPa (81.2 ksi) against 350 MPa (50.8 ksi) for 20MnCr5 Annealed — about 60% more. Tensile strength is 720 MPa (104 ksi) vs 560 MPa (81.2 ksi).

Which condition does FabDigit quote by default, Annealed or CR?

HR is the default 20MnCr5 condition in the FabDigit quote flow (neither Annealed nor CR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 20MnCr5 Annealed or 20MnCr5-CR?

20MnCr5 Annealed, by a small margin. Both rate good for machinability — 65/100 against 55/100 for 20MnCr5-CR.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 20MnCr5 Annealed and 20MnCr5-CR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.