Steel 20MnB-CD vs 20MnB-QT200

Steel · 20MnB temper comparison

20MnB-CD and 20MnB-QT200 are two conditions of the same steel grade, 20MnB: CD (cold drawn) versus QT200 (quenched 860 °C + tempered 200 °C). The chemistry is identical, so every difference below comes from the condition. 20MnB-QT200 is the stronger of the two: yield strength 950 MPa (138 ksi) against 600 MPa (87 ksi) for 20MnB-CD, about 58% more; tensile strength follows at 1,150 MPa (167 ksi) vs 720 MPa (104 ksi). 20MnB-QT200 is harder — 355 HB against 215 HB for 20MnB-CD — which matters for wear surfaces and threads. 20MnB-CD runs hotter in service (250°C vs 180°C continuous). On the shop floor, 20MnB-CD machines more easily (good vs poor), 20MnB-CD welds better (good vs fair), and 20MnB-QT200 forms better (good vs fair).

20MnB-CDChoose it when the part sees heat, or when the part is machined in volume.

20MnB-QT200Choose it when strength drives the design, or when surface hardness matters.

20MnB-CD vs 20MnB-QT200: properties

20MnB-CD20MnB-QT200

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

720 MPa104 ksi
1,150 MPa167 ksi

Yield Strength (0.2% offset)

600 MPa87 ksi
950 MPa138 ksi

Reduction in Area

45%
50%

Compressive Strength

600 MPa87 ksi
400 MPa58 ksi

Shear Strength

435 MPa63.1 ksi
700 MPa102 ksi

Fatigue Strength (Endurance Limit)

340 MPa49.3 ksi
500 MPa72.5 ksi

Fracture Toughness (K_IC)

80 MPa·√m72.8 ksi·√in
90 MPa·√m81.9 ksi·√in

Charpy V-Notch Impact (RT)

40 J29.5 ft·lbf
65 J47.9 ft·lbf

Hardness, Brinell

215 HB
355 HB

Hardness, Rockwell B

95 HRB
88 HRB

Hardness, Vickers

226 HV
375 HV

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Elongation at Break 12%

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,500°C2,732 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

250°C482 °F
180°C356 °F

Same in both: Thermal Conductivity 45 W/m·K26 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.2 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

68 / 100
32 / 100

Machinability Rating (AISI 1212 = 100 %)

70%
30%

Weldability

58 / 100
35 / 100

Formability (cold)

45 / 100
65 / 100

Same in both: Brazeability / Solderability 65 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale20MnB

20MnB-CD vs 20MnB-QT200 — frequently asked

Is 20MnB-QT200 stronger than 20MnB-CD?

Yes. 20MnB-QT200 has a typical yield strength of 950 MPa (138 ksi) against 600 MPa (87 ksi) for 20MnB-CD — about 58% more. Tensile strength is 1,150 MPa (167 ksi) vs 720 MPa (104 ksi).

Which condition does FabDigit quote by default, CD or QT200?

HR is the default 20MnB condition in the FabDigit quote flow (neither CD nor QT200). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 20MnB-CD or 20MnB-QT200?

20MnB-CD. Its machinability rates good (68/100) against poor (32/100) for 20MnB-QT200; for welding the order is 20MnB-CD first (good, 58/100) then 20MnB-QT200 (fair, 35/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 20MnB-CD and 20MnB-QT200 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.