FabDigitFabDigit

Steel 20MC5 +A vs 20MC5-HR

Steel · 20MC5 temper comparison

20MC5 +A and 20MC5-HR are two conditions of the same steel grade, 20MC5: +A (annealed) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. 20MC5-HR is the stronger of the two: yield strength 450 MPa (65.3 ksi) against 400 MPa (58 ksi) for 20MC5 +A, about 13% more; tensile strength follows at 700 MPa (102 ksi) vs 620 MPa (89.9 ksi). In exchange, 20MC5 +A is the more ductile: elongation 22% versus 18% for 20MC5-HR, and 20MC5-HR is harder (215 HB vs 200 HB).

20MC5 +AChoose it when the part is bent, formed or impact-loaded.

20MC5-HRChoose it when strength drives the design.

20MC5 +A vs 20MC5-HR: properties

20MC5 +A20MC5-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

620 MPa89.9 ksi
700 MPa102 ksi

Yield Strength (0.2% offset)

400 MPa58 ksi
450 MPa65.3 ksi

Elongation at Break

22%
18%

Reduction in Area

50%
45%

Shear Strength

400 MPa58 ksi
420 MPa60.9 ksi

Fatigue Strength (Endurance Limit)

290 MPa42.1 ksi
320 MPa46.4 ksi

Fracture Toughness (K_IC)

75 MPa·√m68.3 ksi·√in
72 MPa·√m65.5 ksi·√in

Charpy V-Notch Impact (RT)

60 J44.3 ft·lbf
45 J33.2 ft·lbf

Hardness, Brinell

200 HB
215 HB

Hardness, Rockwell B

93 HRB
94 HRB

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,500°C2,732 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 44 W/m·K25.4 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.7 µm/m·K6.5 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
50 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
55%

Formability (cold)

60 / 100
45 / 100

Same in both: Weldability 40 / 100 · Castability 25 / 100 · Brazeability / Solderability 60 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 29 MJ/kg12,468 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale20MC5

20MC5 +A vs 20MC5-HR — frequently asked

Is 20MC5-HR stronger than 20MC5 +A?

Yes. 20MC5-HR has a typical yield strength of 450 MPa (65.3 ksi) against 400 MPa (58 ksi) for 20MC5 +A — about 13% more. Tensile strength is 700 MPa (102 ksi) vs 620 MPa (89.9 ksi).

Which condition does FabDigit quote by default, +A or HR?

+A is the default 20MC5 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 20MC5 +A or 20MC5-HR?

20MC5 +A. Its machinability rates good (55/100) against fair (50/100) for 20MC5-HR.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 20MC5 +A and 20MC5-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.