FabDigitFabDigit

Steel 20KhN3A-CD vs 20KhN3A N+T

Steel · 20KhN3A temper comparison

20KhN3A-CD and 20KhN3A N+T are two conditions of the same steel grade, 20KhN3A: CD (cold drawn) versus N+T (normalized and tempered). The chemistry is identical, so every difference below comes from the condition. 20KhN3A-CD is the stronger of the two: yield strength 780 MPa (113 ksi) against 560 MPa (81.2 ksi) for 20KhN3A N+T, about 39% more; tensile strength follows at 950 MPa (138 ksi) vs 780 MPa (113 ksi). In exchange, 20KhN3A N+T is the more ductile: elongation 19% versus 10% for 20KhN3A-CD, and 20KhN3A-CD is harder (277 HB vs 223 HB). 20KhN3A N+T runs hotter in service (400°C vs 350°C continuous).

20KhN3A-CDChoose it when strength drives the design.

20KhN3A N+TChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

20KhN3A-CD vs 20KhN3A N+T: properties

20KhN3A-CD20KhN3A N+T

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

208 GPa30.2 Msi
210 GPa30.5 Msi

Tensile Strength (Ultimate)

950 MPa138 ksi
780 MPa113 ksi

Yield Strength (0.2% offset)

780 MPa113 ksi
560 MPa81.2 ksi

Elongation at Break

10%
19%

Reduction in Area

42%
56%

Compressive Strength

800 MPa116 ksi
570 MPa82.7 ksi

Shear Strength

570 MPa82.7 ksi
470 MPa68.2 ksi

Fatigue Strength (Endurance Limit)

410 MPa59.5 ksi
370 MPa53.7 ksi

Fracture Toughness (K_IC)

78 MPa·√m71 ksi·√in
105 MPa·√m95.6 ksi·√in

Charpy V-Notch Impact (RT)

40 J29.5 ft·lbf
72 J53.1 ft·lbf

Hardness, Brinell

277 HB
223 HB

Hardness, Rockwell C

28 HRC
19 HRC

Hardness, Vickers

291 HV
234 HV

Same in both: Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,490°C2,714 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

35 W/m·K20.2 BTU/hr·ft·°F
36 W/m·K20.8 BTU/hr·ft·°F

Max Service Temperature (continuous)

350°C662 °F
400°C752 °F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.8 µm/m·K6.6 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -60°C-76 °F

Electrical

Conductivity and insulation.

Electrical Resistivity

2.85×10⁻⁷ Ω·m11.2 µΩ·in
2.75×10⁻⁷ Ω·m10.8 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 13 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

50 / 100
52 / 100

Machinability Rating (AISI 1212 = 100 %)

52%
55%

Weldability

25 / 100
32 / 100

Formability (cold)

22 / 100
40 / 100

Same in both: Brazeability / Solderability 50 / 100 · Polishability 62 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 34 MJ/kg14,617 BTU/lb · Embodied Carbon (primary production) 2.6 kg CO₂/kg · Embodied Water 65 L/kg7.8 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale20KhN3A

20KhN3A-CD vs 20KhN3A N+T — frequently asked

Is 20KhN3A-CD stronger than 20KhN3A N+T?

Yes. 20KhN3A-CD has a typical yield strength of 780 MPa (113 ksi) against 560 MPa (81.2 ksi) for 20KhN3A N+T — about 39% more. Tensile strength is 950 MPa (138 ksi) vs 780 MPa (113 ksi).

Which condition does FabDigit quote by default, CD or N+T?

Q&T is the default 20KhN3A condition in the FabDigit quote flow (neither CD nor N+T). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, 20KhN3A-CD or 20KhN3A N+T?

20KhN3A N+T. Its weldability rates poor (32/100) against poor (25/100) for 20KhN3A-CD.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 20KhN3A-CD and 20KhN3A N+T side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.