FabDigitFabDigit

Steel 20G-CD vs 20G-HR

Steel · 20G temper comparison

20G-CD and 20G-HR are two conditions of the same steel grade, 20G: CD (cold drawn) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. 20G-CD is the stronger of the two: yield strength 450 MPa (65.3 ksi) against 280 MPa (40.6 ksi) for 20G-HR, about 61% more; tensile strength follows at 560 MPa (81.2 ksi) vs 480 MPa (69.6 ksi). In exchange, 20G-HR is the more ductile: elongation 26% versus 14% for 20G-CD, and 20G-CD is harder (170 HB vs 143 HB). 20G-HR runs hotter in service (425°C vs 350°C continuous).

20G-CDChoose it when strength drives the design.

20G-HRChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

20G-CD vs 20G-HR: properties

20G-CD20G-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

560 MPa81.2 ksi
480 MPa69.6 ksi

Yield Strength (0.2% offset)

450 MPa65.3 ksi
280 MPa40.6 ksi

Elongation at Break

14%
26%

Reduction in Area

45%
55%

Compressive Strength

450 MPa65.3 ksi
280 MPa40.6 ksi

Shear Strength

380 MPa55.1 ksi
335 MPa48.6 ksi

Fatigue Strength (Endurance Limit)

250 MPa36.3 ksi
215 MPa31.2 ksi

Fracture Toughness (K_IC)

80 MPa·√m72.8 ksi·√in
100 MPa·√m91 ksi·√in

Charpy V-Notch Impact (RT)

40 J29.5 ft·lbf
70 J51.6 ft·lbf

Hardness, Brinell

170 HB
143 HB

Hardness, Rockwell B

87 HRB
78 HRB

Hardness, Vickers

179 HV
150 HV

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 81 GPa11.7 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,490°C2,714 °F · Liquidus Temperature 1,520°C2,768 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

350°C662 °F
425°C797 °F

Same in both: Thermal Conductivity 48 W/m·K27.7 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.1 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

10.5 % IACS
11 % IACS

Electrical Resistivity

1.65×10⁻⁷ Ω·m6.5 µΩ·in
1.6×10⁻⁷ Ω·m6.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.65 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

70 / 100
63 / 100

Machinability Rating (AISI 1212 = 100 %)

70%
63%

Weldability

88 / 100
92 / 100

Formability (cold)

55 / 100
78 / 100

Same in both: Brazeability / Solderability 65 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale20G

20G-CD vs 20G-HR — frequently asked

Is 20G-CD stronger than 20G-HR?

Yes. 20G-CD has a typical yield strength of 450 MPa (65.3 ksi) against 280 MPa (40.6 ksi) for 20G-HR — about 61% more. Tensile strength is 560 MPa (81.2 ksi) vs 480 MPa (69.6 ksi).

Which condition does FabDigit quote by default, CD or HR?

N is the default 20G condition in the FabDigit quote flow (neither CD nor HR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 20G-CD or 20G-HR?

20G-CD. Its machinability rates very good (70/100) against good (63/100) for 20G-HR.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 20G-CD and 20G-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.