FabDigitFabDigit

Steel 20Cr-A vs 20Cr-HR

Steel · 20Cr temper comparison

20Cr-A and 20Cr-HR are two conditions of the same steel grade, 20Cr: A (solution annealed) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. 20Cr-HR is the stronger of the two: yield strength 380 MPa (55.1 ksi) against 300 MPa (43.5 ksi) for 20Cr-A, about 27% more; tensile strength follows at 600 MPa (87 ksi) vs 520 MPa (75.4 ksi). In exchange, 20Cr-A is the more ductile: elongation 27% versus 22% for 20Cr-HR, and 20Cr-HR is harder (170 HB vs 156 HB).

20Cr-AChoose it when the part is bent, formed or impact-loaded.

20Cr-HRChoose it when strength drives the design.

20Cr-A vs 20Cr-HR: properties

20Cr-A20Cr-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

520 MPa75.4 ksi
600 MPa87 ksi

Yield Strength (0.2% offset)

300 MPa43.5 ksi
380 MPa55.1 ksi

Elongation at Break

27%
22%

Reduction in Area

58%
50%

Fatigue Strength (Endurance Limit)

250 MPa36.3 ksi
280 MPa40.6 ksi

Charpy V-Notch Impact (RT)

75 J55.3 ft·lbf
60 J44.3 ft·lbf

Hardness, Brinell

156 HB
170 HB

Hardness, Rockwell B

82 HRB
88 HRB

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 380 MPa55.1 ksi · Shear Strength 380 MPa55.1 ksi · Fracture Toughness (K_IC) 90 MPa·√m81.9 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,505°C2,741 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 44 W/m·K25.4 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.9 µm/m·K6.6 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

66 / 100
60 / 100

Machinability Rating (AISI 1212 = 100 %)

70%
65%

Weldability

58 / 100
55 / 100

Formability (cold)

72 / 100
60 / 100

Same in both: Brazeability / Solderability 65 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 27 MJ/kg11,608 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale20Cr

20Cr-A vs 20Cr-HR — frequently asked

Is 20Cr-HR stronger than 20Cr-A?

Yes. 20Cr-HR has a typical yield strength of 380 MPa (55.1 ksi) against 300 MPa (43.5 ksi) for 20Cr-A — about 27% more. Tensile strength is 600 MPa (87 ksi) vs 520 MPa (75.4 ksi).

Which condition does FabDigit quote by default, A or HR?

HR is the default 20Cr condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 20Cr-A or 20Cr-HR?

20Cr-A, by a small margin. Both rate good for machinability — 66/100 against 60/100 for 20Cr-HR.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 20Cr-A and 20Cr-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.