FabDigitFabDigit

Steel 18NCD6-CH vs 18NCD6-HR

Steel · 18NCD6 temper comparison

18NCD6-CH and 18NCD6-HR are two conditions of the same steel grade, 18NCD6: CH (carburized and hardened) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. 18NCD6-CH is the stronger of the two: yield strength 900 MPa (131 ksi) against 440 MPa (63.8 ksi) for 18NCD6-HR, about 105% more; tensile strength follows at 1,150 MPa (167 ksi) vs 700 MPa (102 ksi). In exchange, 18NCD6-HR is the more ductile: elongation 19% versus 11% for 18NCD6-CH, and 18NCD6-HR is harder (207 HB vs 170 HB). 18NCD6-HR runs hotter in service (200°C vs 180°C continuous). On the shop floor, 18NCD6-HR machines more easily (fair vs not recommended) and 18NCD6-HR welds better (fair vs not recommended).

18NCD6-CHChoose it when strength drives the design.

18NCD6-HRChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

18NCD6-CH vs 18NCD6-HR: properties

18NCD6-CH18NCD6-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

1,150 MPa167 ksi
700 MPa102 ksi

Yield Strength (0.2% offset)

900 MPa131 ksi
440 MPa63.8 ksi

Elongation at Break

11%
19%

Shear Strength

380 MPa55.1 ksi
425 MPa61.6 ksi

Fatigue Strength (Endurance Limit)

620 MPa89.9 ksi
315 MPa45.7 ksi

Charpy V-Notch Impact (RT)

35 J25.8 ft·lbf
50 J36.9 ft·lbf

Hardness, Brinell

170 HB
207 HB

Hardness, Rockwell B

87 HRB
94 HRB

Same in both: Elastic (Young's) Modulus 207 GPa30 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Reduction in Area 45%

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,495°C2,723 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

180°C356 °F
200°C392 °F

Same in both: Thermal Conductivity 43 W/m·K24.8 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.6 µm/m·K6.4 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

10 / 100
53 / 100

Machinability Rating (AISI 1212 = 100 %)

8%
58%

Weldability

10 / 100
45 / 100

Formability (cold)

5 / 100
42 / 100

Polishability

80 / 100
65 / 100

Same in both: Brazeability / Solderability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 29 MJ/kg12,468 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale18NCD6

18NCD6-CH vs 18NCD6-HR — frequently asked

Is 18NCD6-CH stronger than 18NCD6-HR?

Yes. 18NCD6-CH has a typical yield strength of 900 MPa (131 ksi) against 440 MPa (63.8 ksi) for 18NCD6-HR — about 105% more. Tensile strength is 1,150 MPa (167 ksi) vs 700 MPa (102 ksi).

Which condition does FabDigit quote by default, CH or HR?

A is the default 18NCD6 condition in the FabDigit quote flow (neither CH nor HR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 18NCD6-CH or 18NCD6-HR?

18NCD6-HR. Its machinability rates fair (53/100) against not recommended (10/100) for 18NCD6-CH; for welding the order is 18NCD6-HR first (fair, 45/100) then 18NCD6-CH (not recommended, 10/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 18NCD6-CH and 18NCD6-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.