18KhGT-N and 18KhGT-QT200 are two conditions of the same steel grade, 18KhGT: N (normalized) versus QT200 (quenched (860–880 °C, oil) + tempered 200 °C). The chemistry is identical, so every difference below comes from the condition. 18KhGT-QT200 is the stronger of the two: yield strength 980 MPa (142 ksi) against 560 MPa (81.2 ksi) for 18KhGT-N, about 75% more; tensile strength follows at 1,150 MPa (167 ksi) vs 820 MPa (119 ksi). In exchange, 18KhGT-N is the more ductile: elongation 16% versus 11% for 18KhGT-QT200, and 18KhGT-QT200 is harder (355 HB vs 217 HB). 18KhGT-N runs hotter in service (350°C vs 180°C continuous). On the shop floor, 18KhGT-N machines more easily (50 vs 35 out of 100) and 18KhGT-N welds better (fair vs poor).

18KhGT-NChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

18KhGT-QT200Choose it when strength drives the design.

18KhGT-N vs 18KhGT-QT200: properties

18KhGT-N18KhGT-QT200

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

820 MPa119 ksi
1,150 MPa167 ksi

Yield Strength (0.2% offset)

560 MPa81.2 ksi
980 MPa142 ksi

Elongation at Break

16%
11%

Reduction in Area

45%
55%

Shear Strength

495 MPa71.8 ksi
700 MPa102 ksi

Fatigue Strength (Endurance Limit)

380 MPa55.1 ksi
500 MPa72.5 ksi

Charpy V-Notch Impact (RT)

65 J47.9 ft·lbf
60 J44.3 ft·lbf

Hardness, Brinell

217 HB
355 HB

Hardness, Rockwell B

96 HRB
92 HRB

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.8 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,490°C2,714 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

350°C662 °F
180°C356 °F

Same in both: Thermal Conductivity 41 W/m·K23.7 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

50 / 100
35 / 100

Machinability Rating (AISI 1212 = 100 %)

50%
35%

Weldability

42 / 100
25 / 100

Formability (cold)

40 / 100
45 / 100

Same in both: Brazeability / Solderability 55 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 34 MJ/kg14,617 BTU/lb · Embodied Carbon (primary production) 2.3 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale18KhGT

18KhGT-N vs 18KhGT-QT200 — frequently asked

Is 18KhGT-QT200 stronger than 18KhGT-N?

Yes. 18KhGT-QT200 has a typical yield strength of 980 MPa (142 ksi) against 560 MPa (81.2 ksi) for 18KhGT-N — about 75% more. Tensile strength is 1,150 MPa (167 ksi) vs 820 MPa (119 ksi).

Which condition does FabDigit quote by default, N or QT200?

HR is the default 18KhGT condition in the FabDigit quote flow (neither N nor QT200). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 18KhGT-N or 18KhGT-QT200?

18KhGT-N, by a small margin. Both rate fair for machinability — 50/100 against 35/100 for 18KhGT-QT200; for welding the order is 18KhGT-N first (fair, 42/100) then 18KhGT-QT200 (poor, 25/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 18KhGT-N and 18KhGT-QT200 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.