FabDigitFabDigit

Steel 18B2 +AC vs 18B2 +U

Steel · 18B2 temper comparison

18B2 +AC and 18B2 +U are two conditions of the same steel grade, 18B2: +AC (spheroidize annealed) versus +U (hot rolled). The chemistry is identical, so every difference below comes from the condition. 18B2 +U is the stronger of the two: yield strength 350 MPa (50.8 ksi) against 270 MPa (39.2 ksi) for 18B2 +AC, about 30% more; tensile strength follows at 540 MPa (78.3 ksi) vs 430 MPa (62.4 ksi). In exchange, 18B2 +AC is the more ductile: elongation 30% versus 24% for 18B2 +U, and 18B2 +U is harder (160 HB vs 130 HB).

18B2 +ACChoose it when the part is bent, formed or impact-loaded.

18B2 +UChoose it when strength drives the design.

18B2 +AC vs 18B2 +U: properties

18B2 +AC18B2 +U

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

430 MPa62.4 ksi
540 MPa78.3 ksi

Yield Strength (0.2% offset)

270 MPa39.2 ksi
350 MPa50.8 ksi

Elongation at Break

30%
24%

Reduction in Area

68%
58%

Shear Strength

280 MPa40.6 ksi
340 MPa49.3 ksi

Fatigue Strength (Endurance Limit)

210 MPa30.5 ksi
255 MPa37 ksi

Charpy V-Notch Impact (RT)

70 J51.6 ft·lbf
55 J40.6 ft·lbf

Hardness, Brinell

130 HB
160 HB

Hardness, Rockwell B

72 HRB
84 HRB

Hardness, Vickers

137 HV
168 HV

Same in both: Elastic (Young's) Modulus 207 GPa30 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,500°C2,732 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 46 W/m·K26.6 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.8 µm/m·K6.6 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 350°C662 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 9.5 % IACS · Electrical Resistivity 1.8×10⁻⁷ Ω·m7.09 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

10 / 100
9 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

52 / 100
58 / 100

Machinability Rating (AISI 1212 = 100 %)

58%
62%

Weldability

70 / 100
68 / 100

Formability (cold)

92 / 100
70 / 100

Same in both: Brazeability / Solderability 60 / 100 · Polishability 50 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale18B2

18B2 +AC vs 18B2 +U — frequently asked

Is 18B2 +U stronger than 18B2 +AC?

Yes. 18B2 +U has a typical yield strength of 350 MPa (50.8 ksi) against 270 MPa (39.2 ksi) for 18B2 +AC — about 30% more. Tensile strength is 540 MPa (78.3 ksi) vs 430 MPa (62.4 ksi).

Which condition does FabDigit quote by default, +AC or +U?

+AC+C is the default 18B2 condition in the FabDigit quote flow (neither +AC nor +U). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 18B2 +AC or 18B2 +U?

18B2 +U. Its machinability rates good (58/100) against fair (52/100) for 18B2 +AC.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 18B2 +AC and 18B2 +U side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.