Steel · 17Cr3 temper comparison

17Cr3 +A and 17Cr3 +U are two conditions of the same steel grade, 17Cr3: +A (annealed) versus +U (hot rolled). The chemistry is identical, so every difference below comes from the condition. 17Cr3 +U is the stronger of the two: yield strength 370 MPa (53.7 ksi) against 310 MPa (45 ksi) for 17Cr3 +A, about 19% more; tensile strength follows at 610 MPa (88.5 ksi) vs 520 MPa (75.4 ksi). In exchange, 17Cr3 +A is the more ductile: elongation 25% versus 19% for 17Cr3 +U, and 17Cr3 +U is harder (175 HB vs 150 HB).

17Cr3 +AChoose it when the part is bent, formed or impact-loaded.

17Cr3 +UChoose it when strength drives the design.

17Cr3 +A vs 17Cr3 +U: properties

17Cr3 +A17Cr3 +U

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

520 MPa75.4 ksi
610 MPa88.5 ksi

Yield Strength (0.2% offset)

310 MPa45 ksi
370 MPa53.7 ksi

Elongation at Break

25%
19%

Reduction in Area

58%
47%

Compressive Strength

370 MPa53.7 ksi
380 MPa55.1 ksi

Shear Strength

400 MPa58 ksi
410 MPa59.5 ksi

Fatigue Strength (Endurance Limit)

280 MPa40.6 ksi
290 MPa42.1 ksi

Fracture Toughness (K_IC)

90 MPa·√m81.9 ksi·√in
85 MPa·√m77.4 ksi·√in

Charpy V-Notch Impact (RT)

85 J62.7 ft·lbf
60 J44.3 ft·lbf

Hardness, Brinell

150 HB
175 HB

Hardness, Rockwell B

87 HRB
88 HRB

Hardness, Vickers

158 HV
185 HV

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 165 GPa23.9 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,495°C2,723 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 44 W/m·K25.4 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.8 µm/m·K6.6 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 350°C662 °F · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 8 % IACS · Electrical Resistivity 2.1×10⁻⁷ Ω·m8.27 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 13 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

58 / 100
55 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
58%

Weldability

62 / 100
60 / 100

Formability (cold)

70 / 100
50 / 100

Same in both: Castability 25 / 100 · Brazeability / Solderability 65 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 30 MJ/kg12,898 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 50 L/kg6 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale17Cr3

17Cr3 +A vs 17Cr3 +U — frequently asked

Is 17Cr3 +U stronger than 17Cr3 +A?

Yes. 17Cr3 +U has a typical yield strength of 370 MPa (53.7 ksi) against 310 MPa (45 ksi) for 17Cr3 +A — about 19% more. Tensile strength is 610 MPa (88.5 ksi) vs 520 MPa (75.4 ksi).

Which condition does FabDigit quote by default, +A or +U?

+FP is the default 17Cr3 condition in the FabDigit quote flow (neither +A nor +U). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 17Cr3 +A over 17Cr3 +U?

Pick 17Cr3 +A when the part is bent, formed or impact-loaded. Pick 17Cr3 +U when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 17Cr3 +A and 17Cr3 +U side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.