FabDigitFabDigit

Steel 17B2 +AC+C vs 17B2 +U

Steel · 17B2 temper comparison

17B2 +AC+C and 17B2 +U are two conditions of the same steel grade, 17B2: +AC+C (spheroidize annealed then cold drawn) versus +U (hot rolled). The chemistry is identical, so every difference below comes from the condition. 17B2 +AC+C is the stronger of the two: yield strength 400 MPa (58 ksi) against 320 MPa (46.4 ksi) for 17B2 +U, about 25% more; tensile strength follows at 520 MPa (75.4 ksi) vs 490 MPa (71.1 ksi). In exchange, 17B2 +U is the more ductile: elongation 22% versus 13% for 17B2 +AC+C.

17B2 +AC+CChoose it when strength drives the design.

17B2 +UChoose it when the part is bent, formed or impact-loaded.

17B2 +AC+C vs 17B2 +U: properties

17B2 +AC+C17B2 +U

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

520 MPa75.4 ksi
490 MPa71.1 ksi

Yield Strength (0.2% offset)

400 MPa58 ksi
320 MPa46.4 ksi

Elongation at Break

13%
22%

Reduction in Area

55%
60%

Shear Strength

330 MPa47.9 ksi
310 MPa45 ksi

Fatigue Strength (Endurance Limit)

250 MPa36.3 ksi
235 MPa34.1 ksi

Charpy V-Notch Impact (RT)

45 J33.2 ft·lbf
50 J36.9 ft·lbf

Hardness, Brinell

150 HB
145 HB

Hardness, Rockwell B

80 HRB
78 HRB

Hardness, Vickers

158 HV
152 HV

Same in both: Elastic (Young's) Modulus 207 GPa30 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,495°C2,723 °F · Liquidus Temperature 1,520°C2,768 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 47 W/m·K27.2 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 300°C572 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 9.5 % IACS · Electrical Resistivity 1.8×10⁻⁷ Ω·m7.09 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

58 / 100
55 / 100

Machinability Rating (AISI 1212 = 100 %)

68%
65%

Formability (cold)

78 / 100
75 / 100

Same in both: Weldability 70 / 100 · Brazeability / Solderability 70 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale17B2

17B2 +AC+C vs 17B2 +U — frequently asked

Is 17B2 +AC+C stronger than 17B2 +U?

Yes. 17B2 +AC+C has a typical yield strength of 400 MPa (58 ksi) against 320 MPa (46.4 ksi) for 17B2 +U — about 25% more. Tensile strength is 520 MPa (75.4 ksi) vs 490 MPa (71.1 ksi).

Which condition does FabDigit quote by default, +AC+C or +U?

+AC+C is the default 17B2 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 17B2 +AC+C over 17B2 +U?

Pick 17B2 +AC+C when strength drives the design. Pick 17B2 +U when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 17B2 +AC+C and 17B2 +U side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.