FabDigitFabDigit

Steel 16NiCr4 +A vs 16NiCr4 +S

Steel · 16NiCr4 temper comparison

16NiCr4 +A and 16NiCr4 +S are two conditions of the same steel grade, 16NiCr4: +A (annealed) versus +S (treated for shearability). The chemistry is identical, so every difference below comes from the condition. 16NiCr4 +A is the stronger of the two: yield strength 370 MPa (53.7 ksi) against 350 MPa (50.8 ksi) for 16NiCr4 +S, about 6% more. 16NiCr4 +A runs hotter in service (400°C vs 200°C continuous).

16NiCr4 +AChoose it when strength drives the design, or when the part sees heat.

16NiCr4 +A vs 16NiCr4 +S: properties

16NiCr4 +A16NiCr4 +S

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

600 MPa87 ksi
580 MPa84.1 ksi

Yield Strength (0.2% offset)

370 MPa53.7 ksi
350 MPa50.8 ksi

Elongation at Break

20%
21%

Reduction in Area

55%
58%

Compressive Strength

370 MPa53.7 ksi
350 MPa50.8 ksi

Shear Strength

390 MPa56.6 ksi
375 MPa54.4 ksi

Fatigue Strength (Endurance Limit)

280 MPa40.6 ksi
270 MPa39.2 ksi

Fracture Toughness (K_IC)

80 MPa·√m72.8 ksi·√in
85 MPa·√m77.4 ksi·√in

Charpy V-Notch Impact (RT)

60 J44.3 ft·lbf
65 J47.9 ft·lbf

Hardness, Brinell

170 HB
165 HB

Hardness, Rockwell B

88 HRB
85 HRB

Hardness, Vickers

180 HV
173 HV

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,500°C2,732 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

400°C752 °F
200°C392 °F

Same in both: Thermal Conductivity 44 W/m·K25.4 BTU/hr·ft·°F · Specific Heat Capacity 465 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.7 µm/m·K6.5 µin/in·°F · Latent Heat of Fusion 247 J/g106 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 8.6 % IACS · Electrical Resistivity 2×10⁻⁷ Ω·m7.87 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.65 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Formability (cold)

65 / 100
70 / 100

Same in both: Machinability 58 / 100 · Machinability Rating (AISI 1212 = 100 %) 62% · Weldability 55 / 100 · Castability 25 / 100 · Brazeability / Solderability 60 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 31 MJ/kg13,328 BTU/lb · Embodied Carbon (primary production) 2.2 kg CO₂/kg · Embodied Water 55 L/kg6.6 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale16NiCr4

16NiCr4 +A vs 16NiCr4 +S — frequently asked

Is 16NiCr4 +A stronger than 16NiCr4 +S?

Yes. 16NiCr4 +A has a typical yield strength of 370 MPa (53.7 ksi) against 350 MPa (50.8 ksi) for 16NiCr4 +S — about 6% more. Tensile strength is 600 MPa (87 ksi) vs 580 MPa (84.1 ksi).

Which condition does FabDigit quote by default, +A or +S?

+A is the default 16NiCr4 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 16NiCr4 +A over 16NiCr4 +S?

Pick 16NiCr4 +A when strength drives the design, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 16NiCr4 +A and 16NiCr4 +S side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.