FabDigitFabDigit

Steel 16MnCr5-CD vs 16MnCr5-CR

Steel · 16MnCr5 temper comparison

16MnCr5-CD and 16MnCr5-CR are two conditions of the same steel grade, 16MnCr5: CD (cold drawn) versus CR (cold rolled). The chemistry is identical, so every difference below comes from the condition. 16MnCr5-CD is the stronger of the two: yield strength 560 MPa (81.2 ksi) against 380 MPa (55.1 ksi) for 16MnCr5-CR, about 47% more; tensile strength follows at 700 MPa (102 ksi) vs 560 MPa (81.2 ksi). In exchange, 16MnCr5-CR is the more ductile: elongation 18% versus 10% for 16MnCr5-CD, and 16MnCr5-CD is harder (215 HB vs 175 HB). On the shop floor, 16MnCr5-CD machines more easily (good vs fair) and 16MnCr5-CR welds better (good vs fair).

16MnCr5-CDChoose it when strength drives the design, or when the part is machined in volume.

16MnCr5-CRChoose it when the part is bent, formed or impact-loaded, or when it will be welded.

16MnCr5-CD vs 16MnCr5-CR: properties

16MnCr5-CD16MnCr5-CR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

700 MPa102 ksi
560 MPa81.2 ksi

Yield Strength (0.2% offset)

560 MPa81.2 ksi
380 MPa55.1 ksi

Elongation at Break

10%
18%

Reduction in Area

40%
50%

Shear Strength

430 MPa62.4 ksi
350 MPa50.8 ksi

Fatigue Strength (Endurance Limit)

320 MPa46.4 ksi
260 MPa37.7 ksi

Fracture Toughness (K_IC)

62 MPa·√m56.4 ksi·√in
75 MPa·√m68.3 ksi·√in

Charpy V-Notch Impact (RT)

35 J25.8 ft·lbf
68 J50.2 ft·lbf

Hardness, Brinell

215 HB
175 HB

Hardness, Vickers

226 HV
185 HV

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,490°C2,714 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 44 W/m·K25.4 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.5 µm/m·K6.4 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 300°C572 °F · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

62 / 100
52 / 100

Machinability Rating (AISI 1212 = 100 %)

65%
55%

Weldability

40 / 100
55 / 100

Formability (cold)

40 / 100
70 / 100

Same in both: Brazeability / Solderability 55 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 27 MJ/kg11,608 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale16MnCr5

16MnCr5-CD vs 16MnCr5-CR — frequently asked

Is 16MnCr5-CD stronger than 16MnCr5-CR?

Yes. 16MnCr5-CD has a typical yield strength of 560 MPa (81.2 ksi) against 380 MPa (55.1 ksi) for 16MnCr5-CR — about 47% more. Tensile strength is 700 MPa (102 ksi) vs 560 MPa (81.2 ksi).

Which condition does FabDigit quote by default, CD or CR?

HR is the default 16MnCr5 condition in the FabDigit quote flow (neither CD nor CR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 16MnCr5-CD or 16MnCr5-CR?

16MnCr5-CD. Its machinability rates good (62/100) against fair (52/100) for 16MnCr5-CR; for welding the order is 16MnCr5-CR first (good, 55/100) then 16MnCr5-CD (fair, 40/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 16MnCr5-CD and 16MnCr5-CR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.