FabDigitFabDigit

Steel 12L14 Annealed vs 12L14-CR

Steel · 12L14 temper comparison

12L14 Annealed and 12L14-CR are two conditions of the same steel grade, 12L14: Annealed versus CR (cold rolled). The chemistry is identical, so every difference below comes from the condition. 12L14-CR is the stronger of the two: yield strength 400 MPa (58 ksi) against 250 MPa (36.3 ksi) for 12L14 Annealed, about 60% more; tensile strength follows at 515 MPa (74.7 ksi) vs 390 MPa (56.6 ksi). In exchange, 12L14 Annealed is the more ductile: elongation 25% versus 12% for 12L14-CR, and 12L14-CR is harder (150 HB vs 111 HB).

12L14 AnnealedChoose it when the part is bent, formed or impact-loaded.

12L14-CRChoose it when strength drives the design.

12L14 Annealed vs 12L14-CR: properties

12L14 Annealed12L14-CR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

390 MPa56.6 ksi
515 MPa74.7 ksi

Yield Strength (0.2% offset)

250 MPa36.3 ksi
400 MPa58 ksi

Elongation at Break

25%
12%

Reduction in Area

50%
38%

Shear Strength

255 MPa37 ksi
335 MPa48.6 ksi

Fatigue Strength (Endurance Limit)

190 MPa27.6 ksi
240 MPa34.8 ksi

Hardness, Brinell

111 HB
150 HB

Hardness, Rockwell B

62 HRB
80 HRB

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.87 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,500°C2,732 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 51.9 W/m·K30 BTU/hr·ft·°F · Specific Heat Capacity 486 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.7 µm/m·K6.5 µin/in·°F · Latent Heat of Fusion 247 J/g106 BTU/lb · Max Service Temperature (continuous) 300°C572 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10.8 % IACS · Electrical Resistivity 1.59×10⁻⁷ Ω·m6.26 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 9 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

88 / 100
96 / 100

Machinability Rating (AISI 1212 = 100 %)

140%
160%

Formability (cold)

45 / 100
32 / 100

Same in both: Weldability 15 / 100 · Brazeability / Solderability 45 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 40 L/kg4.8 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale12L14

12L14 Annealed vs 12L14-CR — frequently asked

Is 12L14-CR stronger than 12L14 Annealed?

Yes. 12L14-CR has a typical yield strength of 400 MPa (58 ksi) against 250 MPa (36.3 ksi) for 12L14 Annealed — about 60% more. Tensile strength is 515 MPa (74.7 ksi) vs 390 MPa (56.6 ksi).

Which condition does FabDigit quote by default, Annealed or CR?

HR is the default 12L14 condition in the FabDigit quote flow (neither Annealed nor CR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 12L14 Annealed or 12L14-CR?

12L14-CR, by a small margin. Both rate excellent for machinability — 96/100 against 88/100 for 12L14 Annealed.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 12L14 Annealed and 12L14-CR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.