FabDigitFabDigit

Steel 12L13 Annealed vs 12L13-CR

Steel · 12L13 temper comparison

12L13 Annealed and 12L13-CR are two conditions of the same steel grade, 12L13: Annealed versus CR (cold rolled). The chemistry is identical, so every difference below comes from the condition. 12L13-CR is the stronger of the two: yield strength 400 MPa (58 ksi) against 220 MPa (31.9 ksi) for 12L13 Annealed, about 82% more; tensile strength follows at 525 MPa (76.1 ksi) vs 380 MPa (55.1 ksi). In exchange, 12L13 Annealed is the more ductile: elongation 28% versus 11% for 12L13-CR, and 12L13-CR is harder (160 HB vs 111 HB).

12L13 AnnealedChoose it when the part is bent, formed or impact-loaded.

12L13-CRChoose it when strength drives the design.

12L13 Annealed vs 12L13-CR: properties

12L13 Annealed12L13-CR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

380 MPa55.1 ksi
525 MPa76.1 ksi

Yield Strength (0.2% offset)

220 MPa31.9 ksi
400 MPa58 ksi

Elongation at Break

28%
11%

Reduction in Area

50%
35%

Shear Strength

240 MPa34.8 ksi
320 MPa46.4 ksi

Fatigue Strength (Endurance Limit)

170 MPa24.7 ksi
235 MPa34.1 ksi

Charpy V-Notch Impact (RT)

20 J14.8 ft·lbf
22 J16.2 ft·lbf

Hardness, Brinell

111 HB
160 HB

Hardness, Rockwell B

64 HRB
83 HRB

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.87 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,505°C2,741 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 51.9 W/m·K30 BTU/hr·ft·°F · Specific Heat Capacity 486 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.7 µm/m·K6.5 µin/in·°F · Latent Heat of Fusion 247 J/g106 BTU/lb · Max Service Temperature (continuous) 250°C482 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10.8 % IACS · Electrical Resistivity 1.6×10⁻⁷ Ω·m6.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

88 / 100
95 / 100

Machinability Rating (AISI 1212 = 100 %)

130%
145%

Formability (cold)

45 / 100
28 / 100

Same in both: Weldability 12 / 100 · Brazeability / Solderability 45 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 50 L/kg6 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale12L13

12L13 Annealed vs 12L13-CR — frequently asked

Is 12L13-CR stronger than 12L13 Annealed?

Yes. 12L13-CR has a typical yield strength of 400 MPa (58 ksi) against 220 MPa (31.9 ksi) for 12L13 Annealed — about 82% more. Tensile strength is 525 MPa (76.1 ksi) vs 380 MPa (55.1 ksi).

Which condition does FabDigit quote by default, Annealed or CR?

HR is the default 12L13 condition in the FabDigit quote flow (neither Annealed nor CR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 12L13 Annealed or 12L13-CR?

12L13-CR, by a small margin. Both rate excellent for machinability — 95/100 against 88/100 for 12L13 Annealed.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 12L13 Annealed and 12L13-CR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.