FabDigitFabDigit

Steel 12KhN3A-CD vs 12KhN3A-HR

Steel · 12KhN3A temper comparison

12KhN3A-CD and 12KhN3A-HR are two conditions of the same steel grade, 12KhN3A: CD (cold drawn) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. 12KhN3A-CD is the stronger of the two: yield strength 660 MPa (95.7 ksi) against 440 MPa (63.8 ksi) for 12KhN3A-HR, about 50% more; tensile strength follows at 800 MPa (116 ksi) vs 700 MPa (102 ksi). In exchange, 12KhN3A-HR is the more ductile: elongation 18% versus 10% for 12KhN3A-CD, and 12KhN3A-CD is harder (240 HB vs 225 HB). 12KhN3A-HR runs hotter in service (350°C vs 250°C continuous). On the shop floor, 12KhN3A-HR welds better (good vs fair).

12KhN3A-CDChoose it when strength drives the design.

12KhN3A-HRChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

12KhN3A-CD vs 12KhN3A-HR: properties

12KhN3A-CD12KhN3A-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

800 MPa116 ksi
700 MPa102 ksi

Yield Strength (0.2% offset)

660 MPa95.7 ksi
440 MPa63.8 ksi

Elongation at Break

10%
18%

Reduction in Area

45%
50%

Compressive Strength

680 MPa98.6 ksi
450 MPa65.3 ksi

Shear Strength

490 MPa71.1 ksi
430 MPa62.4 ksi

Fatigue Strength (Endurance Limit)

360 MPa52.2 ksi
320 MPa46.4 ksi

Fracture Toughness (K_IC)

100 MPa·√m91 ksi·√in
115 MPa·√m105 ksi·√in

Charpy V-Notch Impact (RT)

45 J33.2 ft·lbf
60 J44.3 ft·lbf

Hardness, Brinell

240 HB
225 HB

Hardness, Rockwell C

22 HRC
19 HRC

Hardness, Vickers

253 HV
236 HV

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,495°C2,723 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

38 W/m·K22 BTU/hr·ft·°F
40 W/m·K23.1 BTU/hr·ft·°F

Max Service Temperature (continuous)

250°C482 °F
350°C662 °F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.4 µm/m·K6.3 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -70°C-94 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

7 % IACS
7.5 % IACS

Electrical Resistivity

2.4×10⁻⁷ Ω·m9.45 µΩ·in
2.3×10⁻⁷ Ω·m9.06 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 13 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
50 / 100

Machinability Rating (AISI 1212 = 100 %)

55%
50%

Weldability

45 / 100
55 / 100

Formability (cold)

35 / 100
55 / 100

Same in both: Brazeability / Solderability 55 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 34 MJ/kg14,617 BTU/lb · Embodied Carbon (primary production) 2.5 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale12KhN3A

12KhN3A-CD vs 12KhN3A-HR — frequently asked

Is 12KhN3A-CD stronger than 12KhN3A-HR?

Yes. 12KhN3A-CD has a typical yield strength of 660 MPa (95.7 ksi) against 440 MPa (63.8 ksi) for 12KhN3A-HR — about 50% more. Tensile strength is 800 MPa (116 ksi) vs 700 MPa (102 ksi).

Which condition does FabDigit quote by default, CD or HR?

QT is the default 12KhN3A condition in the FabDigit quote flow (neither CD nor HR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 12KhN3A-CD or 12KhN3A-HR?

12KhN3A-CD. Its machinability rates good (55/100) against fair (50/100) for 12KhN3A-HR; for welding the order is 12KhN3A-HR first (good, 55/100) then 12KhN3A-CD (fair, 45/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 12KhN3A-CD and 12KhN3A-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.