FabDigitFabDigit

Steel 12Cr1MoV-N vs 12Cr1MoV-QT

Steel · 12Cr1MoV temper comparison

12Cr1MoV-N and 12Cr1MoV-QT are two conditions of the same steel grade, 12Cr1MoV: N (normalized) versus QT (quenched and tempered). The chemistry is identical, so every difference below comes from the condition. 12Cr1MoV-QT is the stronger of the two: yield strength 560 MPa (81.2 ksi) against 410 MPa (59.5 ksi) for 12Cr1MoV-N, about 37% more; tensile strength follows at 720 MPa (104 ksi) vs 620 MPa (89.9 ksi). In exchange, 12Cr1MoV-N is the more ductile: elongation 20% versus 18% for 12Cr1MoV-QT, and 12Cr1MoV-QT is harder (215 HB vs 190 HB).

12Cr1MoV-NChoose it when the part is bent, formed or impact-loaded.

12Cr1MoV-QTChoose it when strength drives the design.

12Cr1MoV-N vs 12Cr1MoV-QT: properties

12Cr1MoV-N12Cr1MoV-QT

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

620 MPa89.9 ksi
720 MPa104 ksi

Yield Strength (0.2% offset)

410 MPa59.5 ksi
560 MPa81.2 ksi

Elongation at Break

20%
18%

Reduction in Area

50%
55%

Compressive Strength

415 MPa60.2 ksi
290 MPa42.1 ksi

Shear Strength

375 MPa54.4 ksi
340 MPa49.3 ksi

Fatigue Strength (Endurance Limit)

285 MPa41.3 ksi
320 MPa46.4 ksi

Fracture Toughness (K_IC)

90 MPa·√m81.9 ksi·√in
110 MPa·√m100 ksi·√in

Charpy V-Notch Impact (RT)

60 J44.3 ft·lbf
70 J51.6 ft·lbf

Hardness, Brinell

190 HB
215 HB

Hardness, Rockwell B

91 HRB
83 HRB

Hardness, Vickers

200 HV
168 HV

Same in both: Elastic (Young's) Modulus 212 GPa30.7 Msi · Shear Modulus 82 GPa11.9 Msi · Bulk Modulus 165 GPa23.9 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,490°C2,714 °F · Liquidus Temperature 1,520°C2,768 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

37 W/m·K21.4 BTU/hr·ft·°F
38 W/m·K22 BTU/hr·ft·°F

Max Service Temperature (continuous)

580°C1,076 °F
550°C1,022 °F

Same in both: Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Electrical Resistivity

2.25×10⁻⁷ Ω·m8.86 µΩ·in
2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Corrosion Resistance 22 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

48 / 100
55 / 100

Machinability Rating (AISI 1212 = 100 %)

48%
42%

Weldability

52 / 100
55 / 100

Formability (cold)

42 / 100
50 / 100

Same in both: Brazeability / Solderability 40 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 30 MJ/kg12,898 BTU/lb · Embodied Carbon (primary production) 2.2 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale12Cr1MoV

12Cr1MoV-N vs 12Cr1MoV-QT — frequently asked

Is 12Cr1MoV-QT stronger than 12Cr1MoV-N?

Yes. 12Cr1MoV-QT has a typical yield strength of 560 MPa (81.2 ksi) against 410 MPa (59.5 ksi) for 12Cr1MoV-N — about 37% more. Tensile strength is 720 MPa (104 ksi) vs 620 MPa (89.9 ksi).

Which condition does FabDigit quote by default, N or QT?

N&T is the default 12Cr1MoV condition in the FabDigit quote flow (neither N nor QT). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 12Cr1MoV-N or 12Cr1MoV-QT?

12Cr1MoV-QT. Its machinability rates good (55/100) against fair (48/100) for 12Cr1MoV-N.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 12Cr1MoV-N and 12Cr1MoV-QT side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.