11SMn30 Annealed and 11SMn30-HR are two conditions of the same steel grade, 11SMn30: Annealed versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. 11SMn30-HR is the stronger of the two: yield strength 250 MPa (36.3 ksi) against 230 MPa (33.4 ksi) for 11SMn30 Annealed, about 9% more. In exchange, 11SMn30 Annealed is the more ductile: elongation 26% versus 22% for 11SMn30-HR, and 11SMn30-HR is harder (125 HB vs 112 HB).

11SMn30 AnnealedChoose it when the part is bent, formed or impact-loaded.

11SMn30-HRChoose it when strength drives the design.

11SMn30 Annealed vs 11SMn30-HR: properties

11SMn30 Annealed11SMn30-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

400 MPa58 ksi
420 MPa60.9 ksi

Yield Strength (0.2% offset)

230 MPa33.4 ksi
250 MPa36.3 ksi

Elongation at Break

26%
22%

Reduction in Area

50%
45%

Shear Strength

270 MPa39.2 ksi
290 MPa42.1 ksi

Fatigue Strength (Endurance Limit)

180 MPa26.1 ksi
190 MPa27.6 ksi

Charpy V-Notch Impact (RT)

30 J22.1 ft·lbf
25 J18.4 ft·lbf

Hardness, Brinell

112 HB
125 HB

Hardness, Rockwell B

63 HRB
70 HRB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 420 MPa60.9 ksi · Hardness, Vickers 178 HV

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,495°C2,723 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 50 W/m·K28.9 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.7 µm/m·K6.5 µin/in·°F · Latent Heat of Fusion 247 J/g106 BTU/lb · Max Service Temperature (continuous) 300°C572 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10.5 % IACS · Electrical Resistivity 1.6×10⁻⁷ Ω·m6.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 8 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

85 / 100
82 / 100

Formability (cold)

45 / 100
35 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 120% · Weldability 12 / 100 · Brazeability / Solderability 50 / 100 · Polishability 30 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 50 L/kg6 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale11SMn30

11SMn30 Annealed vs 11SMn30-HR — frequently asked

Is 11SMn30-HR stronger than 11SMn30 Annealed?

Yes. 11SMn30-HR has a typical yield strength of 250 MPa (36.3 ksi) against 230 MPa (33.4 ksi) for 11SMn30 Annealed — about 9% more. Tensile strength is 420 MPa (60.9 ksi) vs 400 MPa (58 ksi).

Which condition does FabDigit quote by default, Annealed or HR?

HR is the default 11SMn30 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 11SMn30 Annealed over 11SMn30-HR?

Pick 11SMn30 Annealed when the part is bent, formed or impact-loaded. Pick 11SMn30-HR when strength drives the design.

Ready to make it?