FabDigitFabDigit

Steel 1146-CR vs 1146 Normalized

Steel · 1146 temper comparison

1146-CR and 1146 Normalized are two conditions of the same steel grade, 1146: CR (cold rolled) versus Normalized. The chemistry is identical, so every difference below comes from the condition. 1146-CR is the stronger of the two: yield strength 550 MPa (79.8 ksi) against 345 MPa (50 ksi) for 1146 Normalized, about 59% more. In exchange, 1146 Normalized is the more ductile: elongation 20% versus 14% for 1146-CR, and 1146-CR is harder (195 HB vs 179 HB). 1146 Normalized runs hotter in service (425°C vs 300°C continuous).

1146-CRChoose it when strength drives the design.

1146 NormalizedChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1146-CR vs 1146 Normalized: properties

1146-CR1146 Normalized

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

650 MPa94.3 ksi
620 MPa89.9 ksi

Yield Strength (0.2% offset)

550 MPa79.8 ksi
345 MPa50 ksi

Elongation at Break

14%
20%

Reduction in Area

33%
43%

Shear Strength

445 MPa64.5 ksi
420 MPa60.9 ksi

Fatigue Strength (Endurance Limit)

295 MPa42.8 ksi
280 MPa40.6 ksi

Charpy V-Notch Impact (RT)

14 J10.3 ft·lbf
22 J16.2 ft·lbf

Hardness, Brinell

195 HB
179 HB

Hardness, Rockwell B

92 HRB
89 HRB

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,490°C2,714 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

300°C572 °F
425°C797 °F

Same in both: Thermal Conductivity 49 W/m·K28.3 BTU/hr·ft·°F · Specific Heat Capacity 486 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.7 µm/m·K6.5 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10 % IACS · Electrical Resistivity 1.7×10⁻⁷ Ω·m6.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

72 / 100
68 / 100

Machinability Rating (AISI 1212 = 100 %)

75%
70%

Weldability

25 / 100
28 / 100

Formability (cold)

22 / 100
35 / 100

Same in both: Brazeability / Solderability 55 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 35 L/kg4.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale1146

1146-CR vs 1146 Normalized — frequently asked

Is 1146-CR stronger than 1146 Normalized?

Yes. 1146-CR has a typical yield strength of 550 MPa (79.8 ksi) against 345 MPa (50 ksi) for 1146 Normalized — about 59% more. Tensile strength is 650 MPa (94.3 ksi) vs 620 MPa (89.9 ksi).

Which condition does FabDigit quote by default, CR or Normalized?

HR is the default 1146 condition in the FabDigit quote flow (neither CR nor Normalized). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 1146-CR over 1146 Normalized?

Pick 1146-CR when strength drives the design. Pick 1146 Normalized when the part is bent, formed or impact-loaded, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1146-CR and 1146 Normalized side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.