FabDigitFabDigit

Steel 1137-CD vs 1137-HR

Steel · 1137 temper comparison

1137-CD and 1137-HR are two conditions of the same steel grade, 1137: CD (cold drawn) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. 1137-CD is the stronger of the two: yield strength 620 MPa (89.9 ksi) against 380 MPa (55.1 ksi) for 1137-HR, about 63% more; tensile strength follows at 725 MPa (105 ksi) vs 620 MPa (89.9 ksi). In exchange, 1137-HR is the more ductile: elongation 15% versus 10% for 1137-CD, and 1137-CD is harder (217 HB vs 179 HB).

1137-CDChoose it when strength drives the design.

1137-HRChoose it when the part is bent, formed or impact-loaded.

1137-CD vs 1137-HR: properties

1137-CD1137-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

725 MPa105 ksi
620 MPa89.9 ksi

Yield Strength (0.2% offset)

620 MPa89.9 ksi
380 MPa55.1 ksi

Elongation at Break

10%
15%

Reduction in Area

30%
35%

Fatigue Strength (Endurance Limit)

320 MPa46.4 ksi
280 MPa40.6 ksi

Charpy V-Notch Impact (RT)

35 J25.8 ft·lbf
60 J44.3 ft·lbf

Hardness, Brinell

217 HB
179 HB

Hardness, Rockwell B

96 HRB
89 HRB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Shear Strength 400 MPa58 ksi

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,500°C2,732 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 48 W/m·K27.7 BTU/hr·ft·°F · Specific Heat Capacity 486 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.7 µm/m·K6.5 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10 % IACS · Electrical Resistivity 1.7×10⁻⁷ Ω·m6.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 9 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

72 / 100
70 / 100

Machinability Rating (AISI 1212 = 100 %)

72%
70%

Formability (cold)

25 / 100
35 / 100

Same in both: Weldability 25 / 100 · Brazeability / Solderability 55 / 100 · Polishability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale1137

1137-CD vs 1137-HR — frequently asked

Is 1137-CD stronger than 1137-HR?

Yes. 1137-CD has a typical yield strength of 620 MPa (89.9 ksi) against 380 MPa (55.1 ksi) for 1137-HR — about 63% more. Tensile strength is 725 MPa (105 ksi) vs 620 MPa (89.9 ksi).

Which condition does FabDigit quote by default, CD or HR?

HR is the default 1137 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 1137-CD over 1137-HR?

Pick 1137-CD when strength drives the design. Pick 1137-HR when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1137-CD and 1137-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.