FabDigitFabDigit

Steel 1117-CR vs 1117-N

Steel · 1117 temper comparison

1117-CR and 1117-N are two conditions of the same steel grade, 1117: CR (cold rolled) versus N (normalized). The chemistry is identical, so every difference below comes from the condition. 1117-CR is the stronger of the two: yield strength 395 MPa (57.3 ksi) against 255 MPa (37 ksi) for 1117-N, about 55% more. In exchange, 1117-N is the more ductile: elongation 31% versus 16% for 1117-CR, and 1117-CR is harder (137 HB vs 130 HB). 1117-N runs hotter in service (400°C vs 350°C continuous).

1117-CRChoose it when strength drives the design.

1117-NChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1117-CR vs 1117-N: properties

1117-CR1117-N

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

470 MPa68.2 ksi
450 MPa65.3 ksi

Yield Strength (0.2% offset)

395 MPa57.3 ksi
255 MPa37 ksi

Elongation at Break

16%
31%

Reduction in Area

42%
56%

Fatigue Strength (Endurance Limit)

230 MPa33.4 ksi
215 MPa31.2 ksi

Charpy V-Notch Impact (RT)

30 J22.1 ft·lbf
55 J40.6 ft·lbf

Hardness, Brinell

137 HB
130 HB

Hardness, Rockwell B

76 HRB
71 HRB

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Shear Strength 300 MPa43.5 ksi

Physical

Density and transition temperatures.

Same in both: Density 7.87 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,500°C2,732 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

350°C662 °F
400°C752 °F

Same in both: Thermal Conductivity 51 W/m·K29.5 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.7 µm/m·K6.5 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

10.5 % IACS
10.8 % IACS

Electrical Resistivity

1.63×10⁻⁷ Ω·m6.42 µΩ·in
1.6×10⁻⁷ Ω·m6.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

74 / 100
68 / 100

Machinability Rating (AISI 1212 = 100 %)

95%
88%

Weldability

48 / 100
52 / 100

Formability (cold)

45 / 100
58 / 100

Same in both: Brazeability / Solderability 65 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale1117

1117-CR vs 1117-N — frequently asked

Is 1117-CR stronger than 1117-N?

Yes. 1117-CR has a typical yield strength of 395 MPa (57.3 ksi) against 255 MPa (37 ksi) for 1117-N — about 55% more. Tensile strength is 470 MPa (68.2 ksi) vs 450 MPa (65.3 ksi).

Which condition does FabDigit quote by default, CR or N?

HR is the default 1117 condition in the FabDigit quote flow (neither CR nor N). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 1117-CR or 1117-N?

1117-CR. Its machinability rates very good (74/100) against good (68/100) for 1117-N.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1117-CR and 1117-N side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.