1055-CD and 1055-N are two conditions of the same steel grade, 1055: CD (cold drawn) versus N (normalized). The chemistry is identical, so every difference below comes from the condition. 1055-CD is the stronger of the two: yield strength 565 MPa (81.9 ksi) against 420 MPa (60.9 ksi) for 1055-N, about 35% more. In exchange, 1055-N is the more ductile: elongation 19% versus 11% for 1055-CD, and 1055-N is harder (217 HB vs 197 HB). 1055-N runs hotter in service (400°C vs 350°C continuous).

1055-CDChoose it when strength drives the design.

1055-NChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1055-CD vs 1055-N: properties

1055-CD1055-N

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

660 MPa95.7 ksi
725 MPa105 ksi

Yield Strength (0.2% offset)

565 MPa81.9 ksi
420 MPa60.9 ksi

Elongation at Break

11%
19%

Reduction in Area

30%
38%

Shear Strength

410 MPa59.5 ksi
400 MPa58 ksi

Fatigue Strength (Endurance Limit)

310 MPa45 ksi
330 MPa47.9 ksi

Charpy V-Notch Impact (RT)

20 J14.8 ft·lbf
24 J17.7 ft·lbf

Hardness, Brinell

197 HB
217 HB

Hardness, Rockwell B

93 HRB
96 HRB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 370 MPa53.7 ksi · Fracture Toughness (K_IC) 60 MPa·√m54.6 ksi·√in · Hardness, Vickers 200 HV

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,490°C2,714 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

350°C662 °F
400°C752 °F

Same in both: Thermal Conductivity 49 W/m·K28.3 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.7 µm/m·K6.5 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 9.5 % IACS · Electrical Resistivity 1.8×10⁻⁷ Ω·m7.09 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
50 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
55%

Weldability

25 / 100
28 / 100

Formability (cold)

25 / 100
30 / 100

Same in both: Castability 40 / 100 · Brazeability / Solderability 60 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 26 MJ/kg11,178 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 50 L/kg6 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale1055

1055-CD vs 1055-N — frequently asked

Is 1055-CD stronger than 1055-N?

Yes. 1055-CD has a typical yield strength of 565 MPa (81.9 ksi) against 420 MPa (60.9 ksi) for 1055-N — about 35% more. Tensile strength is 660 MPa (95.7 ksi) vs 725 MPa (105 ksi).

Which condition does FabDigit quote by default, CD or N?

HR is the default 1055 condition in the FabDigit quote flow (neither CD nor N). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 1055-CD or 1055-N?

1055-CD. Its machinability rates good (55/100) against fair (50/100) for 1055-N.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1055-CD and 1055-N side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.