FabDigitFabDigit

Steel 1045-HR vs 1045-N

Steel · 1045 temper comparison

1045-HR and 1045-N are two conditions of the same steel grade, 1045: HR (hot rolled) versus N (normalized). The chemistry is identical, so every difference below comes from the condition. 1045-N is the stronger of the two: yield strength 340 MPa (49.3 ksi) against 310 MPa (45 ksi) for 1045-HR, about 10% more; tensile strength follows at 620 MPa (89.9 ksi) vs 570 MPa (82.7 ksi). 1045-N is the more ductile: elongation 22% versus 16% for 1045-HR, and 1045-N is harder (179 HB vs 163 HB).

1045-NChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

1045-HR vs 1045-N: properties

1045-HR1045-N

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

570 MPa82.7 ksi
620 MPa89.9 ksi

Yield Strength (0.2% offset)

310 MPa45 ksi
340 MPa49.3 ksi

Elongation at Break

16%
22%

Reduction in Area

40%
51%

Shear Strength

370 MPa53.7 ksi
400 MPa58 ksi

Fatigue Strength (Endurance Limit)

275 MPa39.9 ksi
290 MPa42.1 ksi

Charpy V-Notch Impact (RT)

35 J25.8 ft·lbf
45 J33.2 ft·lbf

Hardness, Brinell

163 HB
179 HB

Hardness, Rockwell B

84 HRB
89 HRB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 540 MPa78.3 ksi · Fracture Toughness (K_IC) 55 MPa·√m50.1 ksi·√in · Hardness, Vickers 188 HV

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,495°C2,723 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 49 W/m·K28.3 BTU/hr·ft·°F · Specific Heat Capacity 486 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.7 µm/m·K6.5 µin/in·°F · Latent Heat of Fusion 247 J/g106 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10.8 % IACS · Electrical Resistivity 1.6×10⁻⁷ Ω·m6.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

50 / 100
52 / 100

Machinability Rating (AISI 1212 = 100 %)

55%
57%

Formability (cold)

50 / 100
35 / 100

Same in both: Weldability 45 / 100 · Castability 55 / 100 · Brazeability / Solderability 65 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 55 L/kg6.6 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale1045

1045-HR vs 1045-N — frequently asked

Is 1045-N stronger than 1045-HR?

Yes. 1045-N has a typical yield strength of 340 MPa (49.3 ksi) against 310 MPa (45 ksi) for 1045-HR — about 10% more. Tensile strength is 620 MPa (89.9 ksi) vs 570 MPa (82.7 ksi).

Which condition does FabDigit quote by default, HR or N?

CD is the default 1045 condition in the FabDigit quote flow (neither HR nor N). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 1045-HR over 1045-N?

Pick 1045-N when strength drives the design, or when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1045-HR and 1045-N side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.