FabDigitFabDigit

Steel 1044-A vs 1044-CD

Steel · 1044 temper comparison

1044-A and 1044-CD are two conditions of the same steel grade, 1044: A (solution annealed) versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. 1044-CD is the stronger of the two: yield strength 565 MPa (81.9 ksi) against 305 MPa (44.2 ksi) for 1044-A, about 85% more; tensile strength follows at 655 MPa (95 ksi) vs 570 MPa (82.7 ksi). In exchange, 1044-A is the more ductile: elongation 24% versus 12% for 1044-CD, and 1044-CD is harder (187 HB vs 163 HB).

1044-AChoose it when the part is bent, formed or impact-loaded.

1044-CDChoose it when strength drives the design.

1044-A vs 1044-CD: properties

1044-A1044-CD

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

570 MPa82.7 ksi
655 MPa95 ksi

Yield Strength (0.2% offset)

305 MPa44.2 ksi
565 MPa81.9 ksi

Elongation at Break

24%
12%

Reduction in Area

45%
35%

Shear Strength

380 MPa55.1 ksi
425 MPa61.6 ksi

Fatigue Strength (Endurance Limit)

265 MPa38.4 ksi
310 MPa45 ksi

Charpy V-Notch Impact (RT)

22 J16.2 ft·lbf
18 J13.3 ft·lbf

Hardness, Brinell

163 HB
187 HB

Hardness, Rockwell B

84 HRB
91 HRB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 310 MPa45 ksi · Fracture Toughness (K_IC) 50 MPa·√m45.5 ksi·√in · Hardness, Vickers 178 HV

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,495°C2,723 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 49 W/m·K28.3 BTU/hr·ft·°F · Specific Heat Capacity 486 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.5 µm/m·K6.4 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10.6 % IACS · Electrical Resistivity 1.62×10⁻⁷ Ω·m6.38 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

58 / 100
60 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
62%

Weldability

58 / 100
50 / 100

Formability (cold)

50 / 100
28 / 100

Same in both: Brazeability / Solderability 65 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 40 L/kg4.8 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale1044

1044-A vs 1044-CD — frequently asked

Is 1044-CD stronger than 1044-A?

Yes. 1044-CD has a typical yield strength of 565 MPa (81.9 ksi) against 305 MPa (44.2 ksi) for 1044-A — about 85% more. Tensile strength is 655 MPa (95 ksi) vs 570 MPa (82.7 ksi).

Which condition does FabDigit quote by default, A or CD?

HR is the default 1044 condition in the FabDigit quote flow (neither A nor CD). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, 1044-A or 1044-CD?

1044-A. Its weldability rates good (58/100) against fair (50/100) for 1044-CD.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1044-A and 1044-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.