FabDigitFabDigit

Steel 1021-A vs 1021-HR

Steel · 1021 temper comparison

1021-A and 1021-HR are two conditions of the same steel grade, 1021: A (solution annealed) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. 1021-A is the stronger of the two: yield strength 295 MPa (42.8 ksi) against 220 MPa (31.9 ksi) for 1021-HR, about 34% more. 1021-A is the more ductile: elongation 36% versus 25% for 1021-HR, and 1021-A is harder (138 HV vs 122 HV).

1021-AChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

1021-A vs 1021-HR: properties

1021-A1021-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

395 MPa57.3 ksi
400 MPa58 ksi

Yield Strength (0.2% offset)

295 MPa42.8 ksi
220 MPa31.9 ksi

Elongation at Break

36%
25%

Reduction in Area

66%
50%

Shear Strength

275 MPa39.9 ksi
250 MPa36.3 ksi

Fatigue Strength (Endurance Limit)

185 MPa26.8 ksi
190 MPa27.6 ksi

Charpy V-Notch Impact (RT)

90 J66.4 ft·lbf
70 J51.6 ft·lbf

Hardness, Brinell

111 HB
116 HB

Hardness, Rockwell B

62 HRB
65 HRB

Hardness, Vickers

138 HV
122 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 385 MPa55.8 ksi · Fracture Toughness (K_IC) 100 MPa·√m91 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 7.87 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,515°C2,759 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 51.9 W/m·K30 BTU/hr·ft·°F · Specific Heat Capacity 486 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.7 µm/m·K6.5 µin/in·°F · Latent Heat of Fusion 247 J/g106 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10.8 % IACS · Electrical Resistivity 1.6×10⁻⁷ Ω·m6.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

62 / 100
58 / 100

Machinability Rating (AISI 1212 = 100 %)

62%
65%

Weldability

94 / 100
93 / 100

Formability (cold)

90 / 100
85 / 100

Same in both: Brazeability / Solderability 75 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 40 L/kg4.8 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale1021

1021-A vs 1021-HR — frequently asked

Is 1021-A stronger than 1021-HR?

Yes. 1021-A has a typical yield strength of 295 MPa (42.8 ksi) against 220 MPa (31.9 ksi) for 1021-HR — about 34% more. Tensile strength is 395 MPa (57.3 ksi) vs 400 MPa (58 ksi).

Which condition does FabDigit quote by default, A or HR?

CD is the default 1021 condition in the FabDigit quote flow (neither A nor HR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 1021-A over 1021-HR?

Pick 1021-A when strength drives the design, or when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1021-A and 1021-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.