FabDigitFabDigit

Steel 1012-CD vs 1012-HR

Steel · 1012 temper comparison

1012-CD and 1012-HR are two conditions of the same steel grade, 1012: CD (cold drawn) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. 1012-CD is the stronger of the two: yield strength 340 MPa (49.3 ksi) against 185 MPa (26.8 ksi) for 1012-HR, about 84% more; tensile strength follows at 400 MPa (58 ksi) vs 330 MPa (47.9 ksi). In exchange, 1012-HR is the more ductile: elongation 28% versus 18% for 1012-CD, and 1012-CD is harder (115 HB vs 95 HB).

1012-CDChoose it when strength drives the design.

1012-HRChoose it when the part is bent, formed or impact-loaded.

1012-CD vs 1012-HR: properties

1012-CD1012-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

400 MPa58 ksi
330 MPa47.9 ksi

Yield Strength (0.2% offset)

340 MPa49.3 ksi
185 MPa26.8 ksi

Elongation at Break

18%
28%

Reduction in Area

45%
55%

Shear Strength

255 MPa37 ksi
220 MPa31.9 ksi

Fatigue Strength (Endurance Limit)

200 MPa29 ksi
165 MPa23.9 ksi

Charpy V-Notch Impact (RT)

50 J36.9 ft·lbf
70 J51.6 ft·lbf

Hardness, Brinell

115 HB
95 HB

Hardness, Rockwell B

67 HRB
55 HRB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Fracture Toughness (K_IC) 110 MPa·√m100 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 7.87 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,495°C2,723 °F · Liquidus Temperature 1,525°C2,777 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 51.9 W/m·K30 BTU/hr·ft·°F · Specific Heat Capacity 486 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10.8 % IACS · Electrical Resistivity 1.6×10⁻⁷ Ω·m6.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

57 / 100
50 / 100

Machinability Rating (AISI 1212 = 100 %)

62%
55%

Weldability

92 / 100
95 / 100

Formability (cold)

60 / 100
85 / 100

Same in both: Brazeability / Solderability 85 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 40 L/kg4.8 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale1012

1012-CD vs 1012-HR — frequently asked

Is 1012-CD stronger than 1012-HR?

Yes. 1012-CD has a typical yield strength of 340 MPa (49.3 ksi) against 185 MPa (26.8 ksi) for 1012-HR — about 84% more. Tensile strength is 400 MPa (58 ksi) vs 330 MPa (47.9 ksi).

Which condition does FabDigit quote by default, CD or HR?

HR is the default 1012 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 1012-CD or 1012-HR?

1012-CD. Its machinability rates good (57/100) against fair (50/100) for 1012-HR.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1012-CD and 1012-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.