FabDigitFabDigit

Steel 1006-CD vs 1006-HR

Steel · 1006 temper comparison

1006-CD and 1006-HR are two conditions of the same steel grade, 1006: CD (cold drawn) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. 1006-CD is the stronger of the two: yield strength 285 MPa (41.3 ksi) against 170 MPa (24.7 ksi) for 1006-HR, about 68% more; tensile strength follows at 330 MPa (47.9 ksi) vs 300 MPa (43.5 ksi). In exchange, 1006-HR is the more ductile: elongation 30% versus 20% for 1006-CD, and 1006-CD is harder (95 HB vs 86 HB).

1006-CDChoose it when strength drives the design.

1006-HRChoose it when the part is bent, formed or impact-loaded.

1006-CD vs 1006-HR: properties

1006-CD1006-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

330 MPa47.9 ksi
300 MPa43.5 ksi

Yield Strength (0.2% offset)

285 MPa41.3 ksi
170 MPa24.7 ksi

Elongation at Break

20%
30%

Reduction in Area

45%
55%

Shear Strength

220 MPa31.9 ksi
200 MPa29 ksi

Fatigue Strength (Endurance Limit)

165 MPa23.9 ksi
150 MPa21.8 ksi

Hardness, Brinell

95 HB
86 HB

Hardness, Rockwell B

55 HRB
41 HRB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Fracture Toughness (K_IC) 130 MPa·√m118 ksi·√in · Charpy V-Notch Impact (RT) 120 J88.5 ft·lbf · Hardness, Vickers 90 HV

Physical

Density and transition temperatures.

Same in both: Density 7.87 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,515°C2,759 °F · Liquidus Temperature 1,535°C2,795 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 65 W/m·K37.6 BTU/hr·ft·°F · Specific Heat Capacity 481 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 247 J/g106 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -30°C-22 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 12 % IACS · Electrical Resistivity 1.43×10⁻⁷ Ω·m5.63 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.65 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

50 / 100
45 / 100

Machinability Rating (AISI 1212 = 100 %)

55%
50%

Weldability

95 / 100
97 / 100

Formability (cold)

80 / 100
95 / 100

Same in both: Castability 35 / 100 · Brazeability / Solderability 80 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 55 L/kg6.6 gal/lb · Typical Recycled Content 28%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale1006

1006-CD vs 1006-HR — frequently asked

Is 1006-CD stronger than 1006-HR?

Yes. 1006-CD has a typical yield strength of 285 MPa (41.3 ksi) against 170 MPa (24.7 ksi) for 1006-HR — about 68% more. Tensile strength is 330 MPa (47.9 ksi) vs 300 MPa (43.5 ksi).

Which condition does FabDigit quote by default, CD or HR?

HR is the default 1006 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 1006-CD or 1006-HR?

1006-CD, by a small margin. Both rate fair for machinability — 50/100 against 45/100 for 1006-HR.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1006-CD and 1006-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.