10#-CD and 10#-CR are two conditions of the same steel grade, 10#: CD (cold drawn) versus CR (cold rolled). The chemistry is identical, so every difference below comes from the condition. 10#-CD is the stronger of the two: yield strength 370 MPa (53.7 ksi) against 210 MPa (30.5 ksi) for 10#-CR, about 76% more; tensile strength follows at 470 MPa (68.2 ksi) vs 340 MPa (49.3 ksi). In exchange, 10#-CR is the more ductile: elongation 32% versus 10% for 10#-CD, and 10#-CD is harder (145 HB vs 110 HB). On the shop floor, 10#-CD machines more easily (good vs fair).

10#-CDChoose it when strength drives the design, or when the part is machined in volume.

10#-CRChoose it when the part is bent, formed or impact-loaded.

10#-CD vs 10#-CR: properties

10#-CD10#-CR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

470 MPa68.2 ksi
340 MPa49.3 ksi

Yield Strength (0.2% offset)

370 MPa53.7 ksi
210 MPa30.5 ksi

Elongation at Break

10%
32%

Reduction in Area

40%
62%

Compressive Strength

230 MPa33.4 ksi
210 MPa30.5 ksi

Shear Strength

285 MPa41.3 ksi
210 MPa30.5 ksi

Fatigue Strength (Endurance Limit)

210 MPa30.5 ksi
150 MPa21.8 ksi

Charpy V-Notch Impact (RT)

60 J44.3 ft·lbf
110 J81.1 ft·lbf

Hardness, Brinell

145 HB
110 HB

Hardness, Rockwell B

78 HRB
62 HRB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Fracture Toughness (K_IC) 110 MPa·√m100 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,495°C2,723 °F · Liquidus Temperature 1,522°C2,772 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

51 W/m·K29.5 BTU/hr·ft·°F
52 W/m·K30 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 475 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.9 µm/m·K6.6 µin/in·°F · Latent Heat of Fusion 247 J/g106 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -30°C-22 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

10.8 % IACS
11 % IACS

Electrical Resistivity

1.6×10⁻⁷ Ω·m6.3 µΩ·in
1.57×10⁻⁷ Ω·m6.18 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.65 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
42 / 100

Machinability Rating (AISI 1212 = 100 %)

65%
52%

Weldability

95 / 100
96 / 100

Formability (cold)

60 / 100
94 / 100

Same in both: Brazeability / Solderability 80 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 40 L/kg4.8 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale10#

10#-CD vs 10#-CR — frequently asked

Is 10#-CD stronger than 10#-CR?

Yes. 10#-CD has a typical yield strength of 370 MPa (53.7 ksi) against 210 MPa (30.5 ksi) for 10#-CR — about 76% more. Tensile strength is 470 MPa (68.2 ksi) vs 340 MPa (49.3 ksi).

Which condition does FabDigit quote by default, CD or CR?

HR is the default 10# condition in the FabDigit quote flow (neither CD nor CR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 10#-CD or 10#-CR?

10#-CD. Its machinability rates good (55/100) against fair (42/100) for 10#-CR.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 10#-CD and 10#-CR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.