Stainless Steel XM-32-H1100 vs XM-32-H900
Stainless Steel · XM-32 temper comparison
XM-32-H1100 and XM-32-H900 are two conditions of the same stainless steel grade, XM-32: H1100 (aged 593 °C (1100 °F) for 4 h) versus H900 (aged 482 °C (900 °F) for 1 h, peak hardness). The chemistry is identical, so every difference below comes from the condition. XM-32-H900 is the stronger of the two: yield strength 1,205 MPa (175 ksi) against 930 MPa (135 ksi) for XM-32-H1100, about 30% more; tensile strength follows at 1,275 MPa (185 ksi) vs 1,035 MPa (150 ksi). In exchange, XM-32-H1100 is the more ductile: elongation 19% versus 14% for XM-32-H900, and XM-32-H1100 is harder (302 HB vs 285 HB). XM-32-H1100 runs hotter in service (500°C vs 400°C continuous).
XM-32-H1100Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.
XM-32-H900Choose it when strength drives the design.
XM-32-H1100 vs XM-32-H900: propertiesHow to read these bars
- One bar per material. A full bar is the highest value among all stainless steel grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
How to read these bars
- One bar per material. A full bar is the highest value among all stainless steel grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
Mechanical
Strength, stiffness, ductility and hardness at room temperature.
Tensile Strength (Ultimate)
Yield Strength (0.2% offset)
Elongation at Break
Reduction in Area
Compressive Strength
Shear Strength
Fatigue Strength (Endurance Limit)
Fracture Toughness (K_IC)
Charpy V-Notch Impact (RT)
Hardness, Brinell
Hardness, Rockwell C
Hardness, Vickers
Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.28
Physical
Density and transition temperatures.
Same in both: Density 7.78 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,450°C2,642 °F
Thermal
How each material carries heat and how hot it can run.
Thermal Conductivity
Max Service Temperature (continuous)
Same in both: Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.8 µm/m·K6 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -75°C-103 °F
Electrical
Conductivity and insulation.
Electrical Conductivity
Electrical Resistivity
Chemical & Environmental
Corrosion and environmental resistance (0–100 scores).
Corrosion Resistance
Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V
Manufacturability
FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.
Machinability
Machinability Rating (AISI 1212 = 100 %)
Weldability
Formability (cold)
Same in both: Castability 45 / 100 · Brazeability / Solderability 50 / 100 · Polishability 70 / 100
Sustainability
Primary-production footprint per kilogram.
Same in both: Embodied Energy (primary production) 62 MJ/kg26,655 BTU/lb · Embodied Carbon (primary production) 4.8 kg CO₂/kg · Embodied Water 90 L/kg10.8 gal/lb · Typical Recycled Content 45%
Strength versus weight
Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.
XM-32-H1100 vs XM-32-H900 — frequently asked
Is XM-32-H900 stronger than XM-32-H1100?
Yes. XM-32-H900 has a typical yield strength of 1,205 MPa (175 ksi) against 930 MPa (135 ksi) for XM-32-H1100 — about 30% more. Tensile strength is 1,275 MPa (185 ksi) vs 1,035 MPa (150 ksi).
Which condition does FabDigit quote by default, H1100 or H900?
A is the default XM-32 condition in the FabDigit quote flow (neither H1100 nor H900). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.
Which is easier to machine, XM-32-H1100 or XM-32-H900?
XM-32-H900, by a small margin. Both rate fair for machinability — 45/100 against 40/100 for XM-32-H1100; for welding the order is XM-32-H900 first (good, 55/100) then XM-32-H1100 (fair, 50/100).
Ready to make it?
Upload a CAD file and FabDigit prices the part in XM-32-H1100 and XM-32-H900 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.
Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.