FabDigitFabDigit

Stainless Steel S32615 Annealed vs S32615-CD

Stainless Steel · S32615 temper comparison

S32615 Annealed and S32615-CD are two conditions of the same stainless steel grade, S32615: Annealed versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. S32615-CD is the stronger of the two: yield strength 520 MPa (75.4 ksi) against 300 MPa (43.5 ksi) for S32615 Annealed, about 73% more; tensile strength follows at 750 MPa (109 ksi) vs 620 MPa (89.9 ksi). In exchange, S32615 Annealed is the more ductile: elongation 40% versus 22% for S32615-CD, and S32615-CD is harder (240 HB vs 180 HB). S32615 Annealed runs hotter in service (850°C vs 400°C continuous).

S32615 AnnealedChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

S32615-CDChoose it when strength drives the design.

S32615 Annealed vs S32615-CD: properties

S32615 AnnealedS32615-CD

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

620 MPa89.9 ksi
750 MPa109 ksi

Yield Strength (0.2% offset)

300 MPa43.5 ksi
520 MPa75.4 ksi

Elongation at Break

40%
22%

Reduction in Area

55%
45%

Compressive Strength

300 MPa43.5 ksi
540 MPa78.3 ksi

Shear Strength

400 MPa58 ksi
470 MPa68.2 ksi

Fatigue Strength (Endurance Limit)

250 MPa36.3 ksi
300 MPa43.5 ksi

Fracture Toughness (K_IC)

200 MPa·√m182 ksi·√in
150 MPa·√m137 ksi·√in

Charpy V-Notch Impact (RT)

90 J66.4 ft·lbf
60 J44.3 ft·lbf

Hardness, Brinell

180 HB
240 HB

Hardness, Rockwell B

88 HRB
100 HRB

Hardness, Vickers

190 HV
250 HV

Same in both: Elastic (Young's) Modulus 190 GPa27.6 Msi · Shear Modulus 73 GPa10.6 Msi · Bulk Modulus 158 GPa22.9 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 7.6 g/cm³0.27 lb/in³ · Melting Point (Solidus) 1,350°C2,462 °F · Liquidus Temperature 1,400°C2,552 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

850°C1,562 °F
400°C752 °F

Same in both: Thermal Conductivity 12 W/m·K6.9 BTU/hr·ft·°F · Specific Heat Capacity 500 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16 µm/m·K8.9 µin/in·°F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Resistivity

9.5×10⁻⁷ Ω·m37.4 µΩ·in
9.6×10⁻⁷ Ω·m37.8 µΩ·in

Same in both: Electrical Conductivity 1.8 % IACS

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

82 / 100
78 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.15 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
35 / 100

Machinability Rating (AISI 1212 = 100 %)

35%
40%

Weldability

55 / 100
50 / 100

Formability (cold)

60 / 100
40 / 100

Same in both: Brazeability / Solderability 45 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 72 MJ/kg30,954 BTU/lb · Embodied Carbon (primary production) 5.2 kg CO₂/kg · Embodied Water 210 L/kg25.2 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scaleS32615

S32615 Annealed vs S32615-CD — frequently asked

Is S32615-CD stronger than S32615 Annealed?

Yes. S32615-CD has a typical yield strength of 520 MPa (75.4 ksi) against 300 MPa (43.5 ksi) for S32615 Annealed — about 73% more. Tensile strength is 750 MPa (109 ksi) vs 620 MPa (89.9 ksi).

Which condition does FabDigit quote by default, Annealed or CD?

Annealed is the default S32615 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, S32615 Annealed or S32615-CD?

S32615-CD. Its machinability rates fair (35/100) against poor (30/100) for S32615 Annealed; for welding the order is S32615 Annealed first (good, 55/100) then S32615-CD (fair, 50/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in S32615 Annealed and S32615-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.