FabDigitFabDigit

Stainless Steel S32050 Annealed vs S32050-CD

Stainless Steel · S32050 temper comparison

S32050 Annealed and S32050-CD are two conditions of the same stainless steel grade, S32050: Annealed versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. S32050-CD is the stronger of the two: yield strength 690 MPa (100 ksi) against 400 MPa (58 ksi) for S32050 Annealed, about 73% more; tensile strength follows at 900 MPa (131 ksi) vs 780 MPa (113 ksi). In exchange, S32050 Annealed is the more ductile: elongation 48% versus 28% for S32050-CD, and S32050-CD is harder (260 HB vs 200 HB). S32050 Annealed runs hotter in service (425°C vs 300°C continuous).

S32050 AnnealedChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

S32050-CDChoose it when strength drives the design.

S32050 Annealed vs S32050-CD: properties

S32050 AnnealedS32050-CD

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

780 MPa113 ksi
900 MPa131 ksi

Yield Strength (0.2% offset)

400 MPa58 ksi
690 MPa100 ksi

Elongation at Break

48%
28%

Reduction in Area

65%
50%

Shear Strength

480 MPa69.6 ksi
550 MPa79.8 ksi

Fatigue Strength (Endurance Limit)

340 MPa49.3 ksi
400 MPa58 ksi

Fracture Toughness (K_IC)

180 MPa·√m164 ksi·√in
140 MPa·√m127 ksi·√in

Charpy V-Notch Impact (RT)

200 J148 ft·lbf
120 J88.5 ft·lbf

Hardness, Brinell

200 HB
260 HB

Hardness, Rockwell B

92 HRB
100 HRB

Hardness, Vickers

210 HV
272 HV

Same in both: Elastic (Young's) Modulus 195 GPa28.3 Msi · Shear Modulus 75 GPa10.9 Msi · Bulk Modulus 163 GPa23.6 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 8 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,320°C2,408 °F · Liquidus Temperature 1,390°C2,534 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

425°C797 °F
300°C572 °F

Same in both: Thermal Conductivity 11.5 W/m·K6.6 BTU/hr·ft·°F · Specific Heat Capacity 500 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 14.8 µm/m·K8.2 µin/in·°F · Latent Heat of Fusion 285 J/g123 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 1.9 % IACS · Electrical Resistivity 9×10⁻⁷ Ω·m35.4 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

82 / 100
80 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.08 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

22 / 100
26 / 100

Machinability Rating (AISI 1212 = 100 %)

25%
30%

Weldability

65 / 100
60 / 100

Formability (cold)

58 / 100
35 / 100

Same in both: Brazeability / Solderability 45 / 100 · Polishability 78 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 75 MJ/kg32,244 BTU/lb · Embodied Carbon (primary production) 5.8 kg CO₂/kg · Embodied Water 210 L/kg25.2 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scaleS32050

S32050 Annealed vs S32050-CD — frequently asked

Is S32050-CD stronger than S32050 Annealed?

Yes. S32050-CD has a typical yield strength of 690 MPa (100 ksi) against 400 MPa (58 ksi) for S32050 Annealed — about 73% more. Tensile strength is 900 MPa (131 ksi) vs 780 MPa (113 ksi).

Which condition does FabDigit quote by default, Annealed or CD?

Annealed is the default S32050 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, S32050 Annealed or S32050-CD?

S32050 Annealed. Its weldability rates good (65/100) against good (60/100) for S32050-CD.

Ready to make it?

Upload a CAD file and FabDigit prices the part in S32050 Annealed and S32050-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.