FabDigitFabDigit

Stainless Steel N08925-AW vs N08925-CW

Stainless Steel · N08925 temper comparison

N08925-AW and N08925-CW are two conditions of the same stainless steel grade, N08925: AW (as-welded deposit) versus CW (cold worked). The chemistry is identical, so every difference below comes from the condition. N08925-CW is the stronger of the two: yield strength 600 MPa (87 ksi) against 350 MPa (50.8 ksi) for N08925-AW, about 71% more; tensile strength follows at 850 MPa (123 ksi) vs 660 MPa (95.7 ksi). In exchange, N08925-AW is the more ductile: elongation 35% versus 30% for N08925-CW, and N08925-CW is harder (250 HB vs 190 HB). N08925-AW runs hotter in service (400°C vs 300°C continuous).

N08925-AWChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

N08925-CWChoose it when strength drives the design.

N08925-AW vs N08925-CW: properties

N08925-AWN08925-CW

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

660 MPa95.7 ksi
850 MPa123 ksi

Yield Strength (0.2% offset)

350 MPa50.8 ksi
600 MPa87 ksi

Elongation at Break

35%
30%

Reduction in Area

45%
50%

Compressive Strength

360 MPa52.2 ksi
620 MPa89.9 ksi

Shear Strength

420 MPa60.9 ksi
520 MPa75.4 ksi

Fatigue Strength (Endurance Limit)

230 MPa33.4 ksi
380 MPa55.1 ksi

Fracture Toughness (K_IC)

130 MPa·√m118 ksi·√in
150 MPa·√m137 ksi·√in

Charpy V-Notch Impact (RT)

110 J81.1 ft·lbf
120 J88.5 ft·lbf

Hardness, Brinell

190 HB
250 HB

Hardness, Rockwell B

90 HRB
100 HRB

Hardness, Vickers

200 HV
265 HV

Same in both: Elastic (Young's) Modulus 195 GPa28.3 Msi · Shear Modulus 75 GPa10.9 Msi · Bulk Modulus 163 GPa23.6 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 8.1 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,320°C2,408 °F · Liquidus Temperature 1,390°C2,534 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

11 W/m·K6.4 BTU/hr·ft·°F
11.5 W/m·K6.6 BTU/hr·ft·°F

Max Service Temperature (continuous)

400°C752 °F
300°C572 °F

Same in both: Specific Heat Capacity 450 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 15.5 µm/m·K8.6 µin/in·°F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

1.7 % IACS
1.8 % IACS

Electrical Resistivity

1.03×10⁻⁶ Ω·m40.6 µΩ·in
1×10⁻⁶ Ω·m39.4 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

80 / 100
85 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.05 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

24 / 100
26 / 100

Machinability Rating (AISI 1212 = 100 %)

22%
30%

Weldability

72 / 100
68 / 100

Same in both: Formability (cold) 45 / 100 · Brazeability / Solderability 55 / 100 · Polishability 72 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 80 MJ/kg34,394 BTU/lb · Embodied Carbon (primary production) 6.5 kg CO₂/kg · Embodied Water 160 L/kg19.2 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scaleN08925

N08925-AW vs N08925-CW — frequently asked

Is N08925-CW stronger than N08925-AW?

Yes. N08925-CW has a typical yield strength of 600 MPa (87 ksi) against 350 MPa (50.8 ksi) for N08925-AW — about 71% more. Tensile strength is 850 MPa (123 ksi) vs 660 MPa (95.7 ksi).

Which condition does FabDigit quote by default, AW or CW?

SA is the default N08925 condition in the FabDigit quote flow (neither AW nor CW). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose N08925-AW over N08925-CW?

Pick N08925-AW when the part is bent, formed or impact-loaded, or when the part sees heat. Pick N08925-CW when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in N08925-AW and N08925-CW side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.