FabDigitFabDigit

Stainless Steel ER630-H1025 vs ER630-H925

Stainless Steel · ER630 temper comparison

ER630-H1025 and ER630-H925 are two conditions of the same stainless steel grade, ER630: H1025 (aged 552 °C (1025 °F) for 4 h) versus H925 (aged 496 °C (925 °F) for 4 h). The chemistry is identical, so every difference below comes from the condition. ER630-H925 is the stronger of the two: yield strength 1,070 MPa (155 ksi) against 1,000 MPa (145 ksi) for ER630-H1025, about 7% more; tensile strength follows at 1,170 MPa (170 ksi) vs 1,070 MPa (155 ksi). In exchange, ER630-H1025 is the more ductile: elongation 13% versus 11% for ER630-H925, and ER630-H925 is harder (390 HB vs 352 HB).

ER630-H1025Choose it when the part is bent, formed or impact-loaded.

ER630-H925Choose it when strength drives the design.

ER630-H1025 vs ER630-H925: properties

ER630-H1025ER630-H925

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

197 GPa28.6 Msi
196 GPa28.4 Msi

Tensile Strength (Ultimate)

1,070 MPa155 ksi
1,170 MPa170 ksi

Yield Strength (0.2% offset)

1,000 MPa145 ksi
1,070 MPa155 ksi

Elongation at Break

13%
11%

Reduction in Area

45%
40%

Compressive Strength

1,035 MPa150 ksi
1,105 MPa160 ksi

Shear Strength

670 MPa97.2 ksi
730 MPa106 ksi

Fatigue Strength (Endurance Limit)

550 MPa79.8 ksi
600 MPa87 ksi

Fracture Toughness (K_IC)

90 MPa·√m81.9 ksi·√in
70 MPa·√m63.7 ksi·√in

Charpy V-Notch Impact (RT)

40 J29.5 ft·lbf
27 J19.9 ft·lbf

Hardness, Brinell

352 HB
390 HB

Hardness, Rockwell C

38 HRC
42 HRC

Hardness, Vickers

372 HV
412 HV

Same in both: Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.27

Physical

Density and transition temperatures.

Same in both: Density 7.78 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,404°C2,559 °F · Liquidus Temperature 1,440°C2,624 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

18.3 W/m·K10.6 BTU/hr·ft·°F
17.8 W/m·K10.3 BTU/hr·ft·°F

Max Service Temperature (continuous)

340°C644 °F
315°C599 °F

Same in both: Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.8 µm/m·K6 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -70°C-94 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

1.7 % IACS
1.8 % IACS

Electrical Resistivity

1.02×10⁻⁶ Ω·m40.2 µΩ·in
9.8×10⁻⁷ Ω·m38.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

55 / 100
50 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.3 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

33 / 100
28 / 100

Machinability Rating (AISI 1212 = 100 %)

38%
32%

Weldability

60 / 100
55 / 100

Formability (cold)

15 / 100
12 / 100

Same in both: Brazeability / Solderability 45 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 53 MJ/kg22,786 BTU/lb · Embodied Carbon (primary production) 5 kg CO₂/kg · Embodied Water 180 L/kg21.6 gal/lb · Typical Recycled Content 50%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scaleER630

ER630-H1025 vs ER630-H925 — frequently asked

Is ER630-H925 stronger than ER630-H1025?

Yes. ER630-H925 has a typical yield strength of 1,070 MPa (155 ksi) against 1,000 MPa (145 ksi) for ER630-H1025 — about 7% more. Tensile strength is 1,170 MPa (170 ksi) vs 1,070 MPa (155 ksi).

Which condition does FabDigit quote by default, H1025 or H925?

AW is the default ER630 condition in the FabDigit quote flow (neither H1025 nor H925). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, ER630-H1025 or ER630-H925?

ER630-H1025, by a small margin. Both rate poor for machinability — 33/100 against 28/100 for ER630-H925; for welding the order is ER630-H1025 first (good, 60/100) then ER630-H925 (good, 55/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in ER630-H1025 and ER630-H925 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.