FabDigitFabDigit

Stainless Steel CB7Cu-2-H1075 vs CB7Cu-2-H900

Stainless Steel · CB7Cu-2 temper comparison

CB7Cu-2-H1075 and CB7Cu-2-H900 are two conditions of the same stainless steel grade, CB7Cu-2: H1075 (aged 579 °C (1075 °F) for 4 h) versus H900 (aged 482 °C (900 °F) for 1 h, peak hardness). The chemistry is identical, so every difference below comes from the condition. CB7Cu-2-H900 is the stronger of the two: yield strength 1,210 MPa (175 ksi) against 930 MPa (135 ksi) for CB7Cu-2-H1075, about 30% more; tensile strength follows at 1,350 MPa (196 ksi) vs 1,035 MPa (150 ksi). In exchange, CB7Cu-2-H1075 is the more ductile: elongation 12% versus 8% for CB7Cu-2-H900, and CB7Cu-2-H900 is harder (415 HB vs 327 HB). On the shop floor, CB7Cu-2-H1075 machines more easily (fair vs poor).

CB7Cu-2-H1075Choose it when the part is bent, formed or impact-loaded, or when the part is machined in volume.

CB7Cu-2-H900Choose it when strength drives the design.

CB7Cu-2-H1075 vs CB7Cu-2-H900: properties

CB7Cu-2-H1075CB7Cu-2-H900

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

1,035 MPa150 ksi
1,350 MPa196 ksi

Yield Strength (0.2% offset)

930 MPa135 ksi
1,210 MPa175 ksi

Elongation at Break

12%
8%

Reduction in Area

37%
25%

Compressive Strength

880 MPa128 ksi
1,240 MPa180 ksi

Shear Strength

640 MPa92.8 ksi
830 MPa120 ksi

Fatigue Strength (Endurance Limit)

490 MPa71.1 ksi
610 MPa88.5 ksi

Fracture Toughness (K_IC)

98 MPa·√m89.2 ksi·√in
60 MPa·√m54.6 ksi·√in

Charpy V-Notch Impact (RT)

40 J29.5 ft·lbf
20 J14.8 ft·lbf

Hardness, Brinell

327 HB
415 HB

Hardness, Rockwell C

35 HRC
44 HRC

Hardness, Vickers

345 HV
440 HV

Same in both: Elastic (Young's) Modulus 196 GPa28.4 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 152 GPa22 Msi · Poisson's Ratio 0.28

Physical

Density and transition temperatures.

Same in both: Density 7.8 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,440°C2,624 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 17.8 W/m·K10.3 BTU/hr·ft·°F · Specific Heat Capacity 420 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.8 µm/m·K6 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 300°C572 °F · Min Service Temperature -73°C-99 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.2 % IACS · Electrical Resistivity 7.7×10⁻⁷ Ω·m30.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

57 / 100
50 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

38 / 100
28 / 100

Machinability Rating (AISI 1212 = 100 %)

34%
25%

Same in both: Weldability 65 / 100 · Formability (cold) 20 / 100 · Castability 68 / 100 · Brazeability / Solderability 45 / 100 · Polishability 78 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 4.2 kg CO₂/kg · Embodied Water 220 L/kg26.4 gal/lb · Typical Recycled Content 70%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scaleCB7Cu-2

CB7Cu-2-H1075 vs CB7Cu-2-H900 — frequently asked

Is CB7Cu-2-H900 stronger than CB7Cu-2-H1075?

Yes. CB7Cu-2-H900 has a typical yield strength of 1,210 MPa (175 ksi) against 930 MPa (135 ksi) for CB7Cu-2-H1075 — about 30% more. Tensile strength is 1,350 MPa (196 ksi) vs 1,035 MPa (150 ksi).

Which condition does FabDigit quote by default, H1075 or H900?

H1100 is the default CB7Cu-2 condition in the FabDigit quote flow (neither H1075 nor H900). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, CB7Cu-2-H1075 or CB7Cu-2-H900?

CB7Cu-2-H1075. Its machinability rates fair (38/100) against poor (28/100) for CB7Cu-2-H900.

Ready to make it?

Upload a CAD file and FabDigit prices the part in CB7Cu-2-H1075 and CB7Cu-2-H900 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.