FabDigitFabDigit

Stainless Steel CB6-F vs CB6 N+T

Stainless Steel · CB6 temper comparison

CB6-F and CB6 N+T are two conditions of the same stainless steel grade, CB6: F (as fabricated) versus N+T (normalized and tempered). The chemistry is identical, so every difference below comes from the condition. CB6-F is the stronger of the two: yield strength 650 MPa (94.3 ksi) against 550 MPa (79.8 ksi) for CB6 N+T, about 18% more; tensile strength follows at 900 MPa (131 ksi) vs 760 MPa (110 ksi). In exchange, CB6 N+T is the more ductile: elongation 16% versus 5% for CB6-F, and CB6-F is harder (340 HB vs 230 HB). CB6 N+T runs hotter in service (620°C vs 480°C continuous). On the shop floor, CB6 N+T machines more easily (fair vs poor) and CB6 N+T welds better (fair vs poor).

CB6-FChoose it when strength drives the design.

CB6 N+TChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

CB6-F vs CB6 N+T: properties

CB6-FCB6 N+T

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

900 MPa131 ksi
760 MPa110 ksi

Yield Strength (0.2% offset)

650 MPa94.3 ksi
550 MPa79.8 ksi

Elongation at Break

5%
16%

Reduction in Area

12%
42%

Compressive Strength

665 MPa96.5 ksi
560 MPa81.2 ksi

Shear Strength

570 MPa82.7 ksi
480 MPa69.6 ksi

Fatigue Strength (Endurance Limit)

385 MPa55.8 ksi
330 MPa47.9 ksi

Fracture Toughness (K_IC)

33 MPa·√m30 ksi·√in
65 MPa·√m59.2 ksi·√in

Charpy V-Notch Impact (RT)

12 J8.9 ft·lbf
40 J29.5 ft·lbf

Hardness, Brinell

340 HB
230 HB

Hardness, Rockwell C

36 HRC
21 HRC

Hardness, Vickers

357 HV
242 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 78 GPa11.3 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.28

Physical

Density and transition temperatures.

Same in both: Density 7.7 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,450°C2,642 °F · Liquidus Temperature 1,510°C2,750 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

24 W/m·K13.9 BTU/hr·ft·°F
25 W/m·K14.4 BTU/hr·ft·°F

Max Service Temperature (continuous)

480°C896 °F
620°C1,148 °F

Same in both: Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.4 µm/m·K5.8 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -30°C-22 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

2.7 % IACS
2.9 % IACS

Electrical Resistivity

6.4×10⁻⁷ Ω·m25.2 µΩ·in
6×10⁻⁷ Ω·m23.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

42 / 100
55 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.3 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

25 / 100
45 / 100

Machinability Rating (AISI 1212 = 100 %)

25%
45%

Weldability

20 / 100
35 / 100

Formability (cold)

4 / 100
12 / 100

Same in both: Castability 65 / 100 · Brazeability / Solderability 40 / 100 · Polishability 72 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 53 MJ/kg22,786 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 90 L/kg10.8 gal/lb · Typical Recycled Content 75%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scaleCB6

CB6-F vs CB6 N+T — frequently asked

Is CB6-F stronger than CB6 N+T?

Yes. CB6-F has a typical yield strength of 650 MPa (94.3 ksi) against 550 MPa (79.8 ksi) for CB6 N+T — about 18% more. Tensile strength is 900 MPa (131 ksi) vs 760 MPa (110 ksi).

Which condition does FabDigit quote by default, F or N+T?

N+T is the default CB6 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, CB6-F or CB6 N+T?

CB6 N+T. Its machinability rates fair (45/100) against poor (25/100) for CB6-F; for welding the order is CB6 N+T first (fair, 35/100) then CB6-F (poor, 20/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in CB6-F and CB6 N+T side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.