FabDigitFabDigit

Stainless Steel Alloy 20 Cold Worked Hard vs Alloy 20 Solution Annealed

Stainless Steel · Alloy 20 temper comparison

Alloy 20 Cold Worked Hard and Alloy 20 Solution Annealed are two conditions of the same stainless steel grade, Alloy 20: Cold Worked Hard (cold Worked) versus Solution Annealed. The chemistry is identical, so every difference below comes from the condition. Alloy 20 Cold Worked Hard is the stronger of the two: yield strength 790 MPa (115 ksi) against 290 MPa (42.1 ksi) for Alloy 20 Solution Annealed, about 172% more; tensile strength follows at 930 MPa (135 ksi) vs 600 MPa (87 ksi). In exchange, Alloy 20 Solution Annealed is the more ductile: elongation 45% versus 12% for Alloy 20 Cold Worked Hard, and Alloy 20 Cold Worked Hard is harder (300 HB vs 155 HB).

Alloy 20 Cold Worked HardChoose it when strength drives the design.

Alloy 20 Solution AnnealedChoose it when the part is bent, formed or impact-loaded.

Alloy 20 Cold Worked Hard vs Alloy 20 Solution Annealed: properties

Alloy 20 Cold Worked HardAlloy 20 Solution Annealed

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

930 MPa135 ksi
600 MPa87 ksi

Yield Strength (0.2% offset)

790 MPa115 ksi
290 MPa42.1 ksi

Elongation at Break

12%
45%

Reduction in Area

60%
65%

Fatigue Strength (Endurance Limit)

380 MPa55.1 ksi
260 MPa37.7 ksi

Charpy V-Notch Impact (RT)

190 J140 ft·lbf
210 J155 ft·lbf

Hardness, Brinell

300 HB
155 HB

Hardness, Rockwell B

85 HRB
82 HRB

Same in both: Elastic (Young's) Modulus 193 GPa28 Msi · Shear Modulus 74 GPa10.7 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.3 · Shear Strength 415 MPa60.2 ksi

Physical

Density and transition temperatures.

Same in both: Density 8.08 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,370°C2,498 °F · Liquidus Temperature 1,425°C2,597 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 12 W/m·K6.9 BTU/hr·ft·°F · Specific Heat Capacity 500 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 14.8 µm/m·K8.2 µin/in·°F · Latent Heat of Fusion 285 J/g123 BTU/lb · Max Service Temperature (continuous) 500°C932 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 1.6 % IACS · Electrical Resistivity 1.08×10⁻⁶ Ω·m42.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

76 / 100
82 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.08 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
38 / 100

Formability (cold)

25 / 100
75 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 40% · Weldability 80 / 100 · Castability 55 / 100 · Brazeability / Solderability 60 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 100 MJ/kg42,992 BTU/lb · Embodied Carbon (primary production) 7.5 kg CO₂/kg · Embodied Water 200 L/kg24 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scaleAlloy 20

Alloy 20 Cold Worked Hard vs Alloy 20 Solution Annealed — frequently asked

Is Alloy 20 Cold Worked Hard stronger than Alloy 20 Solution Annealed?

Yes. Alloy 20 Cold Worked Hard has a typical yield strength of 790 MPa (115 ksi) against 290 MPa (42.1 ksi) for Alloy 20 Solution Annealed — about 172% more. Tensile strength is 930 MPa (135 ksi) vs 600 MPa (87 ksi).

Which condition does FabDigit quote by default, Cold Worked Hard or Solution Annealed?

Annealed is the default Alloy 20 condition in the FabDigit quote flow (neither Cold Worked Hard nor Solution Annealed). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose Alloy 20 Cold Worked Hard over Alloy 20 Solution Annealed?

Pick Alloy 20 Cold Worked Hard when strength drives the design. Pick Alloy 20 Solution Annealed when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in Alloy 20 Cold Worked Hard and Alloy 20 Solution Annealed side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.