FabDigitFabDigit

Stainless Steel 415-A vs 415-CD

Stainless Steel · 415 temper comparison

415-A and 415-CD are two conditions of the same stainless steel grade, 415: A (solution annealed) versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. 415-CD is the stronger of the two: yield strength 780 MPa (113 ksi) against 550 MPa (79.8 ksi) for 415-A, about 42% more; tensile strength follows at 900 MPa (131 ksi) vs 720 MPa (104 ksi). In exchange, 415-A is the more ductile: elongation 22% versus 14% for 415-CD, and 415-CD is harder (285 HB vs 210 HB).

415-AChoose it when the part is bent, formed or impact-loaded.

415-CDChoose it when strength drives the design.

415-A vs 415-CD: properties

415-A415-CD

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

720 MPa104 ksi
900 MPa131 ksi

Yield Strength (0.2% offset)

550 MPa79.8 ksi
780 MPa113 ksi

Elongation at Break

22%
14%

Reduction in Area

65%
50%

Compressive Strength

700 MPa102 ksi
800 MPa116 ksi

Shear Strength

520 MPa75.4 ksi
550 MPa79.8 ksi

Fatigue Strength (Endurance Limit)

340 MPa49.3 ksi
420 MPa60.9 ksi

Fracture Toughness (K_IC)

150 MPa·√m137 ksi·√in
120 MPa·√m109 ksi·√in

Charpy V-Notch Impact (RT)

150 J111 ft·lbf
80 J59 ft·lbf

Hardness, Brinell

210 HB
285 HB

Hardness, Rockwell C

17 HRC
29 HRC

Hardness, Vickers

275 HV
300 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 165 GPa23.9 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 7.7 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,480°C2,696 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 25 W/m·K14.4 BTU/hr·ft·°F · Specific Heat Capacity 430 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.5 µm/m·K5.8 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 450°C842 °F · Min Service Temperature -100°C-148 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.9 % IACS · Electrical Resistivity 6×10⁻⁷ Ω·m23.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

48 / 100
46 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.3 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

48 / 100
42 / 100

Machinability Rating (AISI 1212 = 100 %)

55%
45%

Weldability

72 / 100
65 / 100

Formability (cold)

45 / 100
22 / 100

Same in both: Castability 70 / 100 · Brazeability / Solderability 40 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 53 MJ/kg22,786 BTU/lb · Embodied Carbon (primary production) 4.5 kg CO₂/kg · Embodied Water 140 L/kg16.8 gal/lb · Typical Recycled Content 50%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale415

415-A vs 415-CD — frequently asked

Is 415-CD stronger than 415-A?

Yes. 415-CD has a typical yield strength of 780 MPa (113 ksi) against 550 MPa (79.8 ksi) for 415-A — about 42% more. Tensile strength is 900 MPa (131 ksi) vs 720 MPa (104 ksi).

Which condition does FabDigit quote by default, A or CD?

QT780 is the default 415 condition in the FabDigit quote flow (neither A nor CD). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 415-A or 415-CD?

415-A, by a small margin. Both rate fair for machinability — 48/100 against 42/100 for 415-CD; for welding the order is 415-A first (very good, 72/100) then 415-CD (good, 65/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 415-A and 415-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.