309Cb Annealed and 309Cb-CD are two conditions of the same stainless steel grade, 309Cb: Annealed versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. 309Cb-CD is the stronger of the two: yield strength 480 MPa (69.6 ksi) against 310 MPa (45 ksi) for 309Cb Annealed, about 55% more; tensile strength follows at 720 MPa (104 ksi) vs 620 MPa (89.9 ksi). In exchange, 309Cb Annealed is the more ductile: elongation 45% versus 30% for 309Cb-CD, and 309Cb-CD is harder (200 HB vs 165 HB). 309Cb Annealed runs hotter in service (1,000°C vs 870°C continuous).

309Cb AnnealedChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

309Cb-CDChoose it when strength drives the design.

309Cb Annealed vs 309Cb-CD: properties

309Cb Annealed309Cb-CD

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

620 MPa89.9 ksi
720 MPa104 ksi

Yield Strength (0.2% offset)

310 MPa45 ksi
480 MPa69.6 ksi

Elongation at Break

45%
30%

Reduction in Area

55%
45%

Compressive Strength

310 MPa45 ksi
480 MPa69.6 ksi

Shear Strength

400 MPa58 ksi
440 MPa63.8 ksi

Fatigue Strength (Endurance Limit)

240 MPa34.8 ksi
290 MPa42.1 ksi

Fracture Toughness (K_IC)

180 MPa·√m164 ksi·√in
150 MPa·√m137 ksi·√in

Charpy V-Notch Impact (RT)

150 J111 ft·lbf
110 J81.1 ft·lbf

Hardness, Brinell

165 HB
200 HB

Hardness, Rockwell B

85 HRB
93 HRB

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.98 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,450°C2,642 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

1,000°C1,832 °F
870°C1,598 °F

Same in both: Thermal Conductivity 15.6 W/m·K9 BTU/hr·ft·°F · Specific Heat Capacity 500 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 14.9 µm/m·K8.3 µin/in·°F · Latent Heat of Fusion 285 J/g123 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.2 % IACS · Electrical Resistivity 7.8×10⁻⁷ Ω·m30.7 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

66 / 100
65 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.1 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

38 / 100
42 / 100

Machinability Rating (AISI 1212 = 100 %)

40%
45%

Weldability

80 / 100
78 / 100

Formability (cold)

60 / 100
40 / 100

Same in both: Brazeability / Solderability 60 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 60 MJ/kg25,795 BTU/lb · Embodied Carbon (primary production) 4.8 kg CO₂/kg · Embodied Water 200 L/kg24 gal/lb · Typical Recycled Content 60%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale309Cb

309Cb Annealed vs 309Cb-CD — frequently asked

Is 309Cb-CD stronger than 309Cb Annealed?

Yes. 309Cb-CD has a typical yield strength of 480 MPa (69.6 ksi) against 310 MPa (45 ksi) for 309Cb Annealed — about 55% more. Tensile strength is 720 MPa (104 ksi) vs 620 MPa (89.9 ksi).

Which condition does FabDigit quote by default, Annealed or CD?

Annealed is the default 309Cb condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 309Cb Annealed over 309Cb-CD?

Pick 309Cb Annealed when the part is bent, formed or impact-loaded, or when the part sees heat. Pick 309Cb-CD when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 309Cb Annealed and 309Cb-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.