FabDigitFabDigit

Stainless Steel 2304 Annealed vs 2304 Cold Drawn

Stainless Steel · 2304 temper comparison

2304 Annealed and 2304 Cold Drawn are two conditions of the same stainless steel grade, 2304: Annealed versus Cold Drawn. The chemistry is identical, so every difference below comes from the condition. 2304 Cold Drawn is the stronger of the two: yield strength 650 MPa (94.3 ksi) against 455 MPa (66 ksi) for 2304 Annealed, about 43% more; tensile strength follows at 850 MPa (123 ksi) vs 680 MPa (98.6 ksi). In exchange, 2304 Annealed is the more ductile: elongation 30% versus 20% for 2304 Cold Drawn, and 2304 Cold Drawn is harder (280 HB vs 240 HB).

2304 AnnealedChoose it when the part is bent, formed or impact-loaded.

2304 Cold DrawnChoose it when strength drives the design.

2304 Annealed vs 2304 Cold Drawn: properties

2304 Annealed2304 Cold Drawn

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

680 MPa98.6 ksi
850 MPa123 ksi

Yield Strength (0.2% offset)

455 MPa66 ksi
650 MPa94.3 ksi

Elongation at Break

30%
20%

Reduction in Area

55%
40%

Compressive Strength

470 MPa68.2 ksi
670 MPa97.2 ksi

Shear Strength

420 MPa60.9 ksi
520 MPa75.4 ksi

Fatigue Strength (Endurance Limit)

400 MPa58 ksi
440 MPa63.8 ksi

Fracture Toughness (K_IC)

120 MPa·√m109 ksi·√in
95 MPa·√m86.5 ksi·√in

Charpy V-Notch Impact (RT)

210 J155 ft·lbf
120 J88.5 ft·lbf

Hardness, Brinell

240 HB
280 HB

Hardness, Rockwell C

22 HRC
29 HRC

Hardness, Vickers

250 HV
295 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 150 GPa21.8 Msi · Poisson's Ratio 0.3 · Hardness, Rockwell B 99 HRB

Physical

Density and transition temperatures.

Same in both: Density 7.75 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,385°C2,525 °F · Liquidus Temperature 1,445°C2,633 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 16 W/m·K9.2 BTU/hr·ft·°F · Specific Heat Capacity 480 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 13 µm/m·K7.2 µin/in·°F · Latent Heat of Fusion 275 J/g118 BTU/lb · Max Service Temperature (continuous) 300°C572 °F · Min Service Temperature -50°C-58 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.2 % IACS · Electrical Resistivity 8×10⁻⁷ Ω·m31.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

74 / 100
73 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.15 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
38 / 100

Machinability Rating (AISI 1212 = 100 %)

40%
42%

Weldability

72 / 100
70 / 100

Formability (cold)

55 / 100
35 / 100

Same in both: Castability 45 / 100 · Brazeability / Solderability 40 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 46 MJ/kg19,776 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 100 L/kg12 gal/lb · Typical Recycled Content 70%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale2304

2304 Annealed vs 2304 Cold Drawn — frequently asked

Is 2304 Cold Drawn stronger than 2304 Annealed?

Yes. 2304 Cold Drawn has a typical yield strength of 650 MPa (94.3 ksi) against 455 MPa (66 ksi) for 2304 Annealed — about 43% more. Tensile strength is 850 MPa (123 ksi) vs 680 MPa (98.6 ksi).

Which condition does FabDigit quote by default, Annealed or Cold Drawn?

Solution Annealed is the default 2304 condition in the FabDigit quote flow (neither Annealed nor Cold Drawn). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 2304 Annealed over 2304 Cold Drawn?

Pick 2304 Annealed when the part is bent, formed or impact-loaded. Pick 2304 Cold Drawn when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 2304 Annealed and 2304 Cold Drawn side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.