FabDigitFabDigit

Stainless Steel 2101 As Welded vs 2101 Cold Drawn

Stainless Steel · 2101 temper comparison

2101 As Welded and 2101 Cold Drawn are two conditions of the same stainless steel grade, 2101: As Welded (as-welded deposit) versus Cold Drawn. The chemistry is identical, so every difference below comes from the condition. 2101 Cold Drawn is the stronger of the two: yield strength 700 MPa (102 ksi) against 520 MPa (75.4 ksi) for 2101 As Welded, about 35% more; tensile strength follows at 870 MPa (126 ksi) vs 730 MPa (106 ksi). In exchange, 2101 As Welded is the more ductile: elongation 25% versus 20% for 2101 Cold Drawn, and 2101 Cold Drawn is harder (275 HB vs 240 HB).

2101 As WeldedChoose it when the part is bent, formed or impact-loaded.

2101 Cold DrawnChoose it when strength drives the design.

2101 As Welded vs 2101 Cold Drawn: properties

2101 As Welded2101 Cold Drawn

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

730 MPa106 ksi
870 MPa126 ksi

Yield Strength (0.2% offset)

520 MPa75.4 ksi
700 MPa102 ksi

Elongation at Break

25%
20%

Reduction in Area

40%
45%

Compressive Strength

520 MPa75.4 ksi
710 MPa103 ksi

Shear Strength

440 MPa63.8 ksi
520 MPa75.4 ksi

Fatigue Strength (Endurance Limit)

300 MPa43.5 ksi
460 MPa66.7 ksi

Fracture Toughness (K_IC)

90 MPa·√m81.9 ksi·√in
100 MPa·√m91 ksi·√in

Charpy V-Notch Impact (RT)

80 J59 ft·lbf
90 J66.4 ft·lbf

Hardness, Brinell

240 HB
275 HB

Hardness, Rockwell B

99 HRB
98 HRB

Hardness, Vickers

255 HV
295 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 166 GPa24.1 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 7.8 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,465°C2,669 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 15 W/m·K8.7 BTU/hr·ft·°F · Specific Heat Capacity 500 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 13 µm/m·K7.2 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 300°C572 °F · Min Service Temperature -50°C-58 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.7 % IACS · Electrical Resistivity 6.5×10⁻⁷ Ω·m25.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

60 / 100
65 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.1 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

34 / 100
38 / 100

Machinability Rating (AISI 1212 = 100 %)

27%
30%

Weldability

70 / 100
66 / 100

Formability (cold)

40 / 100
35 / 100

Same in both: Brazeability / Solderability 40 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 48 MJ/kg20,636 BTU/lb · Embodied Carbon (primary production) 3.5 kg CO₂/kg · Embodied Water 90 L/kg10.8 gal/lb · Typical Recycled Content 65%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale2101

2101 As Welded vs 2101 Cold Drawn — frequently asked

Is 2101 Cold Drawn stronger than 2101 As Welded?

Yes. 2101 Cold Drawn has a typical yield strength of 700 MPa (102 ksi) against 520 MPa (75.4 ksi) for 2101 As Welded — about 35% more. Tensile strength is 870 MPa (126 ksi) vs 730 MPa (106 ksi).

Which condition does FabDigit quote by default, As Welded or Cold Drawn?

Solution Annealed is the default 2101 condition in the FabDigit quote flow (neither As Welded nor Cold Drawn). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 2101 As Welded over 2101 Cold Drawn?

Pick 2101 As Welded when the part is bent, formed or impact-loaded. Pick 2101 Cold Drawn when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 2101 As Welded and 2101 Cold Drawn side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.