FabDigitFabDigit

Stainless Steel 15-5 PH-H1150 vs 15-5 PH-H925

Stainless Steel · 15-5 PH temper comparison

15-5 PH-H1150 and 15-5 PH-H925 are two conditions of the same stainless steel grade, 15-5 PH: H1150 (overaged 621 °C (1150 °F) for 4 h, maximum toughness) versus H925 (aged 496 °C (925 °F) for 4 h). The chemistry is identical, so every difference below comes from the condition. 15-5 PH-H925 is the stronger of the two: yield strength 1,160 MPa (168 ksi) against 800 MPa (116 ksi) for 15-5 PH-H1150, about 45% more; tensile strength follows at 1,240 MPa (180 ksi) vs 965 MPa (140 ksi). In exchange, 15-5 PH-H1150 is the more ductile: elongation 18% versus 13% for 15-5 PH-H925, and 15-5 PH-H925 is harder (401 HB vs 302 HB). 15-5 PH-H1150 runs hotter in service (425°C vs 300°C continuous) and 15-5 PH-H1150 conducts heat better (21 W/m·K vs 18 W/m·K). On the shop floor, 15-5 PH-H1150 machines more easily (fair vs poor).

15-5 PH-H1150Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

15-5 PH-H925Choose it when strength drives the design.

15-5 PH-H1150 vs 15-5 PH-H925: properties

15-5 PH-H115015-5 PH-H925

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

965 MPa140 ksi
1,240 MPa180 ksi

Yield Strength (0.2% offset)

800 MPa116 ksi
1,160 MPa168 ksi

Elongation at Break

18%
13%

Reduction in Area

60%
50%

Compressive Strength

810 MPa117 ksi
1,180 MPa171 ksi

Shear Strength

640 MPa92.8 ksi
760 MPa110 ksi

Fatigue Strength (Endurance Limit)

540 MPa78.3 ksi
640 MPa92.8 ksi

Fracture Toughness (K_IC)

140 MPa·√m127 ksi·√in
85 MPa·√m77.4 ksi·√in

Charpy V-Notch Impact (RT)

95 J70.1 ft·lbf
34 J25.1 ft·lbf

Hardness, Brinell

302 HB
401 HB

Hardness, Rockwell C

32 HRC
42 HRC

Hardness, Vickers

330 HV
420 HV

Same in both: Elastic (Young's) Modulus 196 GPa28.4 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 148 GPa21.5 Msi · Poisson's Ratio 0.27

Physical

Density and transition temperatures.

Same in both: Density 7.8 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,440°C2,624 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

21 W/m·K12.1 BTU/hr·ft·°F
18 W/m·K10.4 BTU/hr·ft·°F

Max Service Temperature (continuous)

425°C797 °F
300°C572 °F

Same in both: Specific Heat Capacity 420 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.8 µm/m·K6 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -73°C-99 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.2 % IACS · Electrical Resistivity 8×10⁻⁷ Ω·m31.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

60 / 100
55 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

42 / 100
32 / 100

Machinability Rating (AISI 1212 = 100 %)

45%
33%

Weldability

70 / 100
65 / 100

Formability (cold)

45 / 100
25 / 100

Same in both: Castability 55 / 100 · Brazeability / Solderability 45 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 5.5 kg CO₂/kg · Embodied Water 190 L/kg22.8 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale15-5 PH

15-5 PH-H1150 vs 15-5 PH-H925 — frequently asked

Is 15-5 PH-H925 stronger than 15-5 PH-H1150?

Yes. 15-5 PH-H925 has a typical yield strength of 1,160 MPa (168 ksi) against 800 MPa (116 ksi) for 15-5 PH-H1150 — about 45% more. Tensile strength is 1,240 MPa (180 ksi) vs 965 MPa (140 ksi).

Which condition does FabDigit quote by default, H1150 or H925?

Condition A is the default 15-5 PH condition in the FabDigit quote flow (neither H1150 nor H925). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 15-5 PH-H1150 or 15-5 PH-H925?

15-5 PH-H1150. Its machinability rates fair (42/100) against poor (32/100) for 15-5 PH-H925; for welding the order is 15-5 PH-H1150 first (very good, 70/100) then 15-5 PH-H925 (good, 65/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 15-5 PH-H1150 and 15-5 PH-H925 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.