FabDigitFabDigit

Stainless Steel 15-5 PH-H1100 vs 15-5 PH-H900

Stainless Steel · 15-5 PH temper comparison

15-5 PH-H1100 and 15-5 PH-H900 are two conditions of the same stainless steel grade, 15-5 PH: H1100 (aged 593 °C (1100 °F) for 4 h) versus H900 (aged 482 °C (900 °F) for 1 h, peak hardness). The chemistry is identical, so every difference below comes from the condition. 15-5 PH-H900 is the stronger of the two: yield strength 1,275 MPa (185 ksi) against 900 MPa (131 ksi) for 15-5 PH-H1100, about 42% more; tensile strength follows at 1,380 MPa (200 ksi) vs 1,000 MPa (145 ksi). In exchange, 15-5 PH-H1100 is the more ductile: elongation 16% versus 12% for 15-5 PH-H900, and 15-5 PH-H900 is harder (429 HB vs 321 HB). 15-5 PH-H1100 conducts heat better (20 W/m·K vs 17.9 W/m·K). On the shop floor, 15-5 PH-H1100 machines more easily (fair vs poor).

15-5 PH-H1100Choose it when the part is bent, formed or impact-loaded, or when the part is machined in volume.

15-5 PH-H900Choose it when strength drives the design.

15-5 PH-H1100 vs 15-5 PH-H900: properties

15-5 PH-H110015-5 PH-H900

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

196 GPa28.4 Msi
200 GPa29 Msi

Tensile Strength (Ultimate)

1,000 MPa145 ksi
1,380 MPa200 ksi

Yield Strength (0.2% offset)

900 MPa131 ksi
1,275 MPa185 ksi

Elongation at Break

16%
12%

Reduction in Area

58%
48%

Compressive Strength

940 MPa136 ksi
1,310 MPa190 ksi

Shear Strength

640 MPa92.8 ksi
830 MPa120 ksi

Fatigue Strength (Endurance Limit)

560 MPa81.2 ksi
670 MPa97.2 ksi

Fracture Toughness (K_IC)

115 MPa·√m105 ksi·√in
70 MPa·√m63.7 ksi·√in

Charpy V-Notch Impact (RT)

70 J51.6 ft·lbf
27 J19.9 ft·lbf

Hardness, Brinell

321 HB
429 HB

Hardness, Rockwell C

34 HRC
44 HRC

Hardness, Vickers

335 HV
450 HV

Same in both: Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 148 GPa21.5 Msi · Poisson's Ratio 0.27

Physical

Density and transition temperatures.

Same in both: Density 7.8 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,440°C2,624 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

20 W/m·K11.6 BTU/hr·ft·°F
17.9 W/m·K10.3 BTU/hr·ft·°F

Max Service Temperature (continuous)

315°C599 °F
300°C572 °F

Same in both: Specific Heat Capacity 420 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.8 µm/m·K6 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -73°C-99 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

2.3 % IACS
2.2 % IACS

Same in both: Electrical Resistivity 7.7×10⁻⁷ Ω·m30.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

60 / 100
52 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

44 / 100
28 / 100

Machinability Rating (AISI 1212 = 100 %)

44%
30%

Formability (cold)

40 / 100
10 / 100

Same in both: Weldability 70 / 100 · Castability 55 / 100 · Brazeability / Solderability 45 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 5.5 kg CO₂/kg · Embodied Water 190 L/kg22.8 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale15-5 PH

15-5 PH-H1100 vs 15-5 PH-H900 — frequently asked

Is 15-5 PH-H900 stronger than 15-5 PH-H1100?

Yes. 15-5 PH-H900 has a typical yield strength of 1,275 MPa (185 ksi) against 900 MPa (131 ksi) for 15-5 PH-H1100 — about 42% more. Tensile strength is 1,380 MPa (200 ksi) vs 1,000 MPa (145 ksi).

Which condition does FabDigit quote by default, H1100 or H900?

Condition A is the default 15-5 PH condition in the FabDigit quote flow (neither H1100 nor H900). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 15-5 PH-H1100 or 15-5 PH-H900?

15-5 PH-H1100. Its machinability rates fair (44/100) against poor (28/100) for 15-5 PH-H900.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 15-5 PH-H1100 and 15-5 PH-H900 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.